[siemens_summary]
[catalog_children]
[catalog_search_products]

3VA4/3VA5 ⍾ Page 11

Product detailsAdd to RFQ
3VA5190-6ED11-1AA0 - Siemens
CIRCUIT BREAKER 3VA5 UL FRAME 125 BREAKING CAPACITY CLASS H 50KA @ 277 V 1-POLE, LINE PROTECTION TM210, FTFM, IN=90A OVERLOAD PROTECTION IR=90A FIXED SHORT CIRCUIT PROTECTION II=10 X IN UL489 SB (NAVAL), 50 DEG CEL. W/O CONNECTION
Product detailsAdd to RFQ
3VA5190-6ED31-1AA0 - Siemens
CIRCUIT BREAKER 3VA5 UL FRAME 125 BREAKING CAPACITY CLASS H 65KA @ 480 V 3-POLE, LINE PROTECTION TM210, FTFM, IN=90A OVERLOAD PROTECTION IR=90A FIXED SHORT CIRCUIT PROTECTION II=10 X IN UL489 SB (NAVAL), 50 DEG CEL. W/O CONNECTION
Product detailsAdd to RFQ
3VA5195-1MH31-0AA0 - Siemens
CIRCUIT BREAKER 3VA5 UL FRAME 125 3-POLE,MOTOR STARTER PROTECTION TM120M, FM, IN=15A WITHOUT OVERLOAD PROTECTION SHORT CIRCUIT PROTECTION II=5...12 X IN W/O CONNECTION
Product detailsAdd to RFQ
3VA5195-5EC31-0AA0 - Siemens
CIRCUIT BREAKER 3VA5 UL FRAME 125 BREAKING CAPACITY CLASS M 35KA @ 480 V 3-POLE, LINE PROTECTION TM230, FTAM, IN=15A OVERLOAD PROTECTION IR=15A FIXED SHORT CIRCUIT PROTECTION II=5...10 X IN W/O CONNECTION
Product detailsAdd to RFQ
3VA5190-6EC31-1AA0 - Siemens
CIRCUIT BREAKER 3VA5 UL FRAME 125 BREAKING CAPACITY CLASS H 65KA @ 480 V 3-POLE, LINE PROTECTION TM230, FTAM, IN=90A OVERLOAD PROTECTION IR=90A FIXED SHORT CIRCUIT PROTECTION II=5...10 X IN UL489 SB (NAVAL), 50 DEG CEL. W/O CONNECTION
Product detailsAdd to RFQ
3VA5190-6EC31-0AA0 - Siemens
CIRCUIT BREAKER 3VA5 UL FRAME 125 BREAKING CAPACITY CLASS H 65KA @ 480 V 3-POLE, LINE PROTECTION TM230, FTAM, IN=90A OVERLOAD PROTECTION IR=90A FIXED SHORT CIRCUIT PROTECTION II=5...10 X IN W/O CONNECTION
Product detailsAdd to RFQ
3VA5195-1MU31-0AA0 - Siemens
CIRCUIT BREAKER 3VA5 UL FRAME 125 3-POLE,MOTOR STARTER PROTECTION TM120M, FM, IN=15A WITHOUT OVERLOAD PROTECTION SHORT CIRCUIT PROTECTION II=3...7 X IN W/O CONNECTION
Product detailsAdd to RFQ
3VA5190-6ED31-0AA0 - Siemens
Circuit breaker 3VA5 UL Frame 125 breaking capacity class H 65 kA @ 480 V 3-pole, line protection TM210, FTFM, In=90 A overload protection Ir=90 A permanently set short-circuit protection Ii=10 x In without connection
Product detailsAdd to RFQ
3VA5190-6ED11-0AA0 - Siemens
CIRCUIT BREAKER 3VA5 UL FRAME 125 BREAKING CAPACITY CLASS H 50KA @ 277 V 1-POLE, LINE PROTECTION TM210, FTFM, IN=90A OVERLOAD PROTECTION IR=90A FIXED SHORT CIRCUIT PROTECTION II=10 X IN W/O CONNECTION
Product detailsAdd to RFQ
3VA5190-5ED31-1AA0 - Siemens
CIRCUIT BREAKER 3VA5 UL FRAME 125 BREAKING CAPACITY CLASS M 35KA @ 480 V 3-POLE, LINE PROTECTION TM210, FTFM, IN=90A OVERLOAD PROTECTION IR=90A FIXED SHORT CIRCUIT PROTECTION II=10 X IN UL489 SB (NAVAL), 50 DEG CEL. W/O CONNECTION
Product detailsAdd to RFQ
3VA5190-5ED31-0AA0 - Siemens
CIRCUIT BREAKER 3VA5 UL FRAME 125 BREAKING CAPACITY CLASS M 35KA @ 480 V 3-POLE, LINE PROTECTION TM210, FTFM, IN=90A OVERLOAD PROTECTION IR=90A FIXED SHORT CIRCUIT PROTECTION II=10 X IN W/O CONNECTION
Product detailsAdd to RFQ
3VA5195-4EC31-1AA0 - Siemens
CIRCUIT BREAKER 3VA5 UL FRAME 125 BREAKING CAPACITY CLASS S 25KA @ 480 V 3-POLE, LINE PROTECTION TM230, FTAM, IN=15A OVERLOAD PROTECTION IR=15A FIXED SHORT CIRCUIT PROTECTION II=5...10 X IN UL489 SB (NAVAL), 50 DEG CEL. W/O CONNECTION