[siemens_summary]
[catalog_children]
[catalog_search_products]

3VL ⍾ Page 155

Product detailsAdd to RFQ
3VL4725-1EC46-8CB1 - Siemens
Circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=250A, rated current IR=200...250A, overload protection, II=1200...2500A, short-circuit protection N protected Shunt release 24 V AC/DC Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)
Product detailsAdd to RFQ
3VL4720-1DC36-0AA0 - Siemens
Circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=200A, rated current IR=160...200A, overload protection, II=1000...2000A, short-circuit protection without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL4720-3DC36-0AA0 - Siemens
Circuit breaker VL400L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=200A, rated current IR=160...200A, overload protection, II=1000...2000A, short-circuit protection without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL4140-1KN30-0AA0 - Siemens
Circuit breaker VL400 UL; type JG (cat no. NJX3B400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) Electronic Trip Unit TM, LI TA=40°C In=< 400A, rated current II=2000..4000A short-circuit protection IR=400A Electronic Trip Unit for line protection without connection accessories without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL4140-2KN30-0AA0 - Siemens
Circuit breaker VL400 UL; type JG (cat no. HJX3B400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) Electronic Trip Unit TM, LI TA=40°C In=< 400A, rated current II=2000..4000A short-circuit protection IR=400A Electronic Trip Unit for line protection without connection accessories without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL4140-2KE30-0AA0 - Siemens
Circuit breaker VL400 UL; type JG (cat no. HJS3S400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case switch) Electronic Trip Unit magnetic TA=40°C In=< 400A, rated current II=4400A short-circuit protection non-auto. air circuit breaker without connection accessories without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL4140-2PB30-0AB1 - Siemens
Circuit breaker VL400 UL; type JG (cat no. HJX3R400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) Electronic Trip Unit ETU, LI TA=40°C In=400A, rated current II=1.25 to 11xIN, short-circuit protection IR=150-400A ETU for line protection without connection accessories without auxiliary release Auxiliary switch mounting kit 2...
Product detailsAdd to RFQ
3VL4140-2KK30-0AA0 - Siemens
Circuit breaker VL400 UL; type JG (cat no. HJM3M400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (motor starter protector) Electronic Trip Unit magnetic TA=40°C In=< 400A, rated current II=2000..4000A short-circuit protection starter combination without connection accessories without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL4720-1DK36-0AA0 - Siemens
Circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, starter combination Electronic Trip Unit magnetic In=200A, rated current II=1250...2500A, short-circuit protection without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL4130-2KN30-0AA0 - Siemens
CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3B300) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN= < 300A, RATED CURRENT II= 1500...3000A SHORT-CIRCUIT PROTECTION IR= 300A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VL4130-1KN30-0AA0 - Siemens
Circuit breaker VL400 UL; type JG (cat no. NJX3B300) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) Electronic Trip Unit TM, LI TA=40°C In=< 300A, rated current II=1500...3000A short-circuit protection IR=300A Electronic Trip Unit for line protection without connection accessories without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL4135-2KN30-0AA0 - Siemens
CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3B350) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN= < 350A, RATED CURRENT II= 1750...3500A SHORT-CIRCUIT PROTECTION IR= 350A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH