3VL4135-2KN30-0AA0 - Siemens
CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3B350) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN= < 350A, RATED CURRENT II= 1750...3500A SHORT-CIRCUIT PROTECTION IR= 350A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VL3725-3SL36-0AA0 - Siemens
Circuit breaker VL250L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU12, LIG 3 phases/3 lines In=250A, rated current IR=100...250A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL3725-3SB36-0AD1 - Siemens
Circuit breaker VL250L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=250A, rated current IR=100...250A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)
Product detailsAdd to RFQ
3VL3725-3SS36-0AA0 - Siemens
CIRCUIT-BREAKER VL 250L VERY HIGH BREAKING CAPACITY R.U.S.-C.BR.C.= 100 KA, 415V AC 3-POLE, MOTOR PROTECTION ELECTRONIC TRIP UNIT ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VL3725-3DK36-0AD1 - Siemens
Circuit breaker VL250L very high breaking capacity Icu=100kA, 415V AC 3-pole, starter combination Trip Unit magnetic In=250A, rated current II=1750...3500A, short-circuit protection without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)
Product detailsAdd to RFQ
3VL3725-3SB36-0AA0 - Siemens
Circuit breaker VL250L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=250A, rated current IR=100...250A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL3725-3SP36-0AD1 - Siemens
Circuit breaker VL250L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=250A, rated current IR=100...250A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)
Product detailsAdd to RFQ
3VL3725-3TN46-0AA0 - Siemens
CIRCUIT-BREAKER VL 250L VERY HIGH BREAKING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION ELECTRONIC TRIP UNIT ETU12, LIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VL4125-1PE30-0AA0 - Siemens
Circuit breaker VL400 UL; type JG (cat no. NJX3T250) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) Electronic Trip Unit ETU, LSI TA=40°C In=250A, rated current ISD=1.5 to 10xIR, II=11X in short-circuit protection IR=70-250A Electronic Trip Unit for line protection without connection accessories without auxiliary release without...
Product detailsAdd to RFQ
3VL3725-3SB33-0AD1 - Siemens
Circuit breaker VL250L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=250A, rated current IR=100...250A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release with box terminal Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)
Product detailsAdd to RFQ
3VL3725-2SL36-0AB1 - Siemens
Circuit breaker VL250H High switching capacity Icu=70 kA, 415V AC 3-pole, system protection Overcurrent release ETU12, LIG 3 phases/3 cables In=250 A, Rated current Ir=100...250 A, Overload protection, II=1.25 to 11xIn, Short-circuit protection without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)
Product detailsAdd to RFQ
3VL3725-3DC36-8TE1 - Siemens
CIRCUIT-BREAKER VL 250L VERY HIGH BREAKING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=250A, RATED CURRENT IR=200-250A, OVERLOAD II=1200-2500A, SHORT-CIRCUIT SHUNT RELEASE 208 - 277 V AC