[siemens_summary]
[catalog_children]
[catalog_search_products]

3VL2 (50 ... 160 A) ⍾ Page 21

Product detailsAdd to RFQ
3VL2705-1DC33-2DB1 - Siemens
CIRCUIT-BREAKER VL 160N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=40-50A, OVERLOAD II=300-600A, SHORT CIRCUIT UNDERVOLTAGE RELEASE 24V AC AUXILIARY SWITCH KIT 2HS(1NO+1NC)
Product detailsAdd to RFQ
3VL2705-1EJ43-8KD1 - Siemens
Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=50A, rated current Ir=40...50A, overload prot. II=300...600A, short-circuit protection, N unprotected N unprotected Shunt release 110...127 V DC Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)
Product detailsAdd to RFQ
3VL2705-1EJ43-0AA0 - Siemens
Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=50A, rated current Ir=40...50A, overload prot. II=300...600A, short-circuit protection, N unprotected N unprotected without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL2706-1DC33-0AA0 - Siemens
Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=63A, rated current Ir=50...63A, overload protection, II=300...600A, short-circuit protection without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL2511-2KN30-0AB1 - Siemens
Circuit breaker VL150 UL Type DG (CAT NO. HDK3B110) non-interchangeable frame, with approval circuit breaker according to UL 489 High switching capacity 3-pole; NEMA rating 65 kA @ 480 V and 18 kA @ 600/347 V (molded case circuit breaker) Overcurrent release TM, LI TU=40 °C In=110 A, Rated current II=550...1100 A Short-circuit protection Ir=110 A overcurrent release for system...
Product detailsAdd to RFQ
3VL2512-1KN30-0AD1 - Siemens
Circuit breaker VL150 UL type DG (cat no. NDK3B125) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit TM, LI TA=40°C In=125A, rated current II=625...1250A short-circuit protection Ir=125A Electronic Trip Unit for line protection without connection accessories without auxiliary release Auxiliary/alarm switch mounting...
Product detailsAdd to RFQ
3VL2705-2DC33-0AA0 - Siemens
Circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=50A, rated current Ir=40...50A, overload prot. II=300...600A, short-circuit protection, protection without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL2591-1KN30-0AD1 - Siemens
Circuit breaker VL150 UL type DG (cat no. NDK3B090) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit TM, LI TA=40°C In=90A, rated current II=500...1000A short-circuit protection Ir=90A Electronic Trip Unit for line protection without connection accessories without auxiliary release Auxiliary/alarm switch mounting...
Product detailsAdd to RFQ
3VL2705-1DC33-0AA0 - Siemens
Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=50A, rated current Ir=40...50A, overload prot. II=300...600A, short-circuit protection, protection without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL2515-1VH30-0AA0 - Siemens
Circuit breaker VL150 UL type DG (cat no. NDK3A150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LI/LS/LSI TA=40°C In=150A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL2515-1KN30-0AA0 - Siemens
CIRCUIT-BREAKER VL 150 UL TYPE DG (CAT NO. NDK3B150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER ACC. UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA@480V AND 18KA@600/347V (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=150A, RATED CURRENT II= 800...1600A SHORT-CIRCUIT PROTECTION IR= 150A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VL2515-1PE30-0AB1 - Siemens
Circuit breaker VL150 UL Type DG (CAT NO. NDK3T150) non-interchangeable frame, with approval circuit breaker according to UL 489 Standard switching capacity 3-pole; NEMA rating 35 kA @ 480 V and 18 kA @ 600/347 V (molded case circuit breaker) Overcurrent release ETU, LSI TU=40 °C In=150 A, Rated current ISD=1.5-10xIR, II=11xIn Short-circuit protection Ir=60-150A overcurrent release for system protection...