3VL7112-5KN30-0AA0 - Siemens
BREAKER VL 3P 1200A 480V 35KA FX TM 100 CAT NUMBER NNY3B120
Product detailsAdd to RFQ
3VL7112-6KN30-0AA0 - Siemens
BREAKER VL 3P 1200A 480V 65KA FX TM 100 CAT NUMBER HNY3B120
Product detailsAdd to RFQ
3VL7110-3KN30-0AA0 - Siemens
Circuit breaker VL1200 UL; type NG (cat no. HNX3B100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40°C In=< 1000A, rated current II=6000...10000A short-circuit protection IR=1000A ETU for line protection without connection accessories without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL7112-1PB30-0AA0 - Siemens
Circuit breaker VL1200 UL; type NG (cat no. NNX3R120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) trip unit ETU, LI TA=40°C In=1200A, rated current II=1.25 to 10xIN, short-circuit protection IR=400-1200A overcurrent rel. for line protection without connection accessories without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL7110-2KN30-0AA0 - Siemens
CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. HNX3B100) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN= < 1000A, RATED CURRENT II= 6000...10000A SHORT-CIRCUIT PROTECTION IR= 1000A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VL7110-1KN30-0AA0 - Siemens
Circuit breaker VL1200 UL; Type NG (CAT NO. NNX3B100) non-interchangeable frame, with approval circuit breaker according to UL 489 Standard switching capacity 3-pole, NEMA rating 35 kA/480 V, (molded case circuit breaker) Overcurrent release TM, LI TU=40 °C In=< 1000 A, Rated current II=6000...10000 A Short-circuit protection Ir=1000 A overcurrent release for system protection without connection accessories without auxiliary release...
Product detailsAdd to RFQ
3VL7112-2KE30-8VA0 - Siemens
Circuit breaker VL1200 UL; type NG (cat no. HNS3S120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case switch) trip unit magnetic TA=40°C In=< 1200A, rated current II=12000A short-circuit protection non-auto. air circuit breaker without connection accessories Shunt release 380...600 V AC without auxiliary/alarm switch
Product detailsAdd to RFQ
3VL7112-2KE30-0AA0 - Siemens
Circuit breaker VL1200 UL; type NG (cat no. HNS3S120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case switch) trip unit magnetic TA=40°C In=< 1200A, rated current II=12000A short-circuit protection non-auto. air circuit breaker without connection accessories without auxiliary release without auxiliary/alarm switch