[siemens_summary]
[catalog_children]
[catalog_search_products]
7MB2011 / Continuous gas analyzers

7MB2011 / Continuous gas analyzers

Items 1 - 9 of 9 from Siemens ⍾ Last modified Sep 5, 2025

7MB2011 / Continuous gas analyzers ⍾ Page 1

Product detailsAdd to RFQ
7MB2011-3CB00-0AA1-Z B01 - Siemens
OXYMAT 6 gas analyzer, for field installation Ferrule screw connection made of titanium, pipe with 1/4" outer diameter 2% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of tantalum , None Standard unit and acc. to ATEX II 3G version (Zone 2): 100 to 120 V AC, 48 to 63 Hz Without Without English Kalrez gaskets in sample gas...
Product detailsAdd to RFQ
7MB2011-0EA01-0AB3 - Siemens
OXYMAT 6 gas analyzer, for field installation Ferrule screw connection made of stainless steel (mat. no. 1.4571) pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel mat. No. 1.4571 not documented With heating (65 to 130°C) Standard unit and acc. to ATEX II 3G version (Zone 2): 100 to 120...
Product detailsAdd to RFQ
7MB2011-0EE00-1BA1 - Siemens
OXYMAT 6 gas analyzer, for field installation Ferrule screw connection made of stainless steel (mat. no. 1.4571) pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of Hastelloy not documented Without heating Standard unit and acc. to ATEX II 3G version (Zone 2): 200 to 240 V AC, 48 to 63 Hz With...
Product detailsAdd to RFQ
7MB2011-0EB00-3BA1 - Siemens
OXYMAT 6F GAS ANALYSATOR FOR WALL MOUNT UNIT PRESSURE EQUIPMENT DIRECTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP INTERNAL STUB MADE OF STAIN- LESS STEEL MAT. NO. 1.4571; CONNECTIONS 6 MM SMALLEST POSSIBLE SPAN 5%; REFERENCE GAS INLET PRESSURE 3 BAR MEASURING CELL WITHOUT FLOW- TYPE COMPENSATION BRANCH, MADE OF TANTALUM , WITHOUT INTERNAL HEATING OF THE PHYSICAL PART. POWER...
Product detailsAdd to RFQ
7MB2011-1AB00-1AA1-Z D02 - Siemens
OXYMAT 6 gas analyzer, for field installation Ferrule screw connection made of stainless steel (mat. no. 1.4571) pipe with 1/4" outer diameter 0.5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of tantalum not documented Without heating Standard unit and acc. to ATEX II 3G version (Zone 2): 200 to 240 V AC, 48 to 63 Hz Without reference...
Product detailsAdd to RFQ
7MB2011-1EA00-0BA1 - Siemens
OXYMAT 6 gas analyzer, for field installation Ferrule screw connection made of stainless steel (mat. no. 1.4571) pipe with 1/4" outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel mat. No. 1.4571 not documented Without heating Standard unit and acc. to ATEX II 3G version (Zone 2): 100 to 120 V AC, 48 to...
Product detailsAdd to RFQ
7MB2011-1AB00-0BA1-Z B01 - Siemens
OXYMAT 6 gas analyzer, for field installation Ferrule screw connection made of stainless steel (mat. no. 1.4571) pipe with 1/4" outer diameter 0.5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of tantalum not documented Without heating Standard unit and acc. to ATEX II 3G version (Zone 2): 100 to 120 V AC, 48 to 63 Hz With reference...
Product detailsAdd to RFQ
7MB2011-0EA00-1AA1 - Siemens
OXYMAT 6 gas analyzer, for field installation Ferrule screw connection made of stainless steel (mat. no. 1.4571) pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel mat. No. 1.4571 , None Standard unit and acc. to ATEX II 3G version (Zone 2): 200 to 240 V AC, 48 to 63...
Product detailsAdd to RFQ
7MB2011-0CA00-1AA1 - Siemens
OXYMAT 6 gas analyzer, for field installation Ferrule screw connection made of stainless steel (mat. no. 1.4571) pipe with 6 mm outer diameter 2% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel mat. No. 1.4571 , None Standard unit and acc. to ATEX II 3G version (Zone 2): 200 to 240 V AC, 48 to 63...