7MB6121 / Continuous gas analyzers

7MB6121 / Continuous gas analyzers

Items 1 - 12 of 19 from Siemens ⍾ Last modified Sep 5, 2025

7MB6121 / Continuous gas analyzers ⍾ Page 1

Product detailsAdd to RFQ
7MB6121-1MA01-0XX1 - Siemens
LDS 6 Diode laser spectrometer, Central unit, Without Ex-protection, suitable for connection to CD 6 Ex-variant. Non-Ex area: LDS 6 according to IECEx/ATEX II (1) G _ [Ex op is IIC T4 Ga] IIC; ATEX II (1) D _ [Ex op is IIIC T135°C Da] IIIC; Ta: 5°C...+45°C, Barrier Box according to IECEx/ATEX II (1) G _ [Ex ia op...
Product detailsAdd to RFQ
7MB6121-0KD00-0XX1-Z A31 - Siemens
LDS 6 Diode laser spectrometer, Central unit, without, not suitable for connection to Ex Sensors Measured components: CO/CO2 Application Channel 1: Process control With sensor electronics with CD 6 sensor sensor alignment kit . Application Channel 2: not used Application Channel 3: not used Documentation language: English Telescopic rails (2 units)
Product detailsAdd to RFQ
7MB6121-0KD00-0DD1-Z A31 - Siemens
LDS 6 Diode laser spectrometer, Central unit, without, not suitable for connection to Ex Sensors Measured components: CO/CO2 Application Channel 1: Process control With sensor electronics with CD 6 sensor sensor alignment kit . Application Channel 2: Process control Application Channel 3: Control (defined processes) Documentation language: English Telescopic rails (2 units)
Product detailsAdd to RFQ
7MB6121-0KD00-0XX1 - Siemens
LDS 6 Diode laser spectrometer, Central unit, without, not suitable for connection to Ex Sensors Measured components: CO/CO2 Application Channel 1: Process control With sensor electronics with CD 6 sensor sensor alignment kit . Application Channel 2: not used Application Channel 3: not used Documentation language: English
Product detailsAdd to RFQ
7MB6121-1KD00-0XX1 - Siemens
LDS 6 Diode laser spectrometer, Central unit, Without Ex-protection, suitable for connection to CD 6 Ex-variant. Non-Ex area: LDS 6 according to IECEx/ATEX II (1) G _ [Ex op is IIC T4 Ga] IIC; ATEX II (1) D _ [Ex op is IIIC T135°C Da] IIIC; Ta: 5°C...+45°C, Barrier Box according to IECEx/ATEX II (1) G _ [Ex ia op...
Product detailsAdd to RFQ
7MB6121-1DA00-0XX1 - Siemens
LDS 6 Diode laser spectrometer, Central unit, Without Ex-protection, suitable for connection to CD 6 Ex-variant. Non-Ex area: LDS 6 according to IECEx/ATEX II (1) G _ [Ex op is IIC T4 Ga] IIC; ATEX II (1) D _ [Ex op is IIIC T135°C Da] IIIC; Ta: 5°C...+45°C, Barrier Box according to IECEx/ATEX II (1) G _ [Ex ia op...
Product detailsAdd to RFQ
7MB6121-0CF00-0XX1 - Siemens
LDS 6 Diode laser spectrometer, Central unit, without, not suitable for connection to Ex Sensors Measured component: NH3 Application Channel 1: SCR-DeNOx With sensor electronics with CD 6 sensor sensor alignment kit . Application Channel 2: not used Application Channel 3: not used Documentation language: English
Product detailsAdd to RFQ
7MB6121-1KD00-0DD1-Z A31 - Siemens
LDS 6 Diode laser spectrometer, Central unit, without, suitabel for connection to Ex Sensors in accordance with ATEX II 1 G Ex ia op is IIC T4 Ga, II 1 D Ex ia op is IIIC T135 °Cel Da Measured components: CO/CO2 Application Channel 1: Process control With sensor electronics with CD 6 sensor sensor alignment kit . Application Channel...
Product detailsAdd to RFQ
7MB6121-1KD00-0XX1-Z A31 - Siemens
LDS 6 Diode laser spectrometer, Central unit, without, suitabel for connection to Ex Sensors in accordance with ATEX II 1 G Ex ia op is IIC T4 Ga, II 1 D Ex ia op is IIIC T135 °Cel Da Measured components: CO/CO2 Application Channel 1: Process control With sensor electronics with CD 6 sensor sensor alignment kit . Application Channel...
Product detailsAdd to RFQ
7MB6121-0MA01-0XX1 - Siemens
LDS 6 Diode laser spectrometer, Central unit, Without explosion protection. Connection to CD 6 Ex variant not possible Measured component: H2O Application Channel 1: Emission monitoring, non-certified With sensor electronics without CD 6 sensor sensor alignment kit . Application Channel 2: not used Application Channel 3: not used preset system language: English
Product detailsAdd to RFQ
7MB6121-0FT01-0XX1 - Siemens
LDS 6 Diode laser spectrometer, Central unit, without, not suitable for connection to Ex Sensors Measured components: HCI/H2O Application Channel 1: Emission measuerement, device desing in accordance with QAL1 certification acc. to EN 14181 and EN 15267. Notice: Only in combination with measuring component version C (NH3), D (NH3/H2O), M (H2O), E (HCl) and F (HCl/H2O) With sensor electronics without...
Product detailsAdd to RFQ
7MB6121-0CT00-0XX1 - Siemens
LDS 6 Diode laser spectrometer, Central unit, Without Ex-protection, not suitable for connection to CD 6 Ex-variant Measured component: NH3 Application Channel 1: Emission measuerement, device desing in accordance with QAL1 certification acc. to EN 14181 and EN 15267. Notice: Only in combination with measuring component version C (NH3), D (NH3/H2O), M (H2O), E (HCl) and F (HCl/H2O) With sensor...