7SR ⍾ Page 5

Product detailsAdd to RFQ
7SR2247-2MB22-0CA0 - Siemens
RECLOSER-M DIRECTIONAL. OVERCURRENT RELAY E12 CASE, 4 CT, 4 VT, 33 BINARY INP./ 30 BINARY OUTP. 16 LEDS + 12 KEYS MEASURING INPUT: 1/5 A 63.5/ 110V, AUXILIARY VOLTAGE: 24 - 250V DC / 100-230V AC BINARY INPUT THRESHOLD 19V DC (RATED: 24-250V DC) REGION WORLD, 50/60HZ, FASCIA S LAGUAGE ENGLISH (CHANGEABLE) USB FRONT PORT, RS485 REAR PORT + REAR...
Product detailsAdd to RFQ
7SR2302-1MA87-0CA0 - Siemens
HIGH IMPEDANCE PROTECTION RELAY CIRCULATING CURRENT (4 POLE FUNCTIONALITY) E6 CASE, 4 CT, 8 LEDS, 9 BINARY INPUTS/ 8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 24 - 250V DC / 100-230V AC BINARY INPUT THRESHOLD 19V DC (RATED: 24-250V DC) . USB FRONT PORT, RS485 REAR PORT + REAR OPTICAL ETHERNET DUPLEX PROTOCOL: IEC 60870-5-103 AND MODBUS RTU...
Product detailsAdd to RFQ
7SR2203-2NA12-0EA0 - Siemens
ARGUS-M DIRECTIONAL. OVERCURRENT RELAY CASE SIZE E8, 5 CT,4 VT,16LEDS, 13 BINARY INP./14 BINARY OUTP. MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ USB FRONT PORT, RS485 REAR PORT IEC 60870-5-103, MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION PLUS AUTORECLOSE (79) + (25) CHECK Auxiliary voltage: 24 - 250 V DC / 100-230 V AC Binary...
Product detailsAdd to RFQ
7SR2203-2NA11-0EA0 - Siemens
ARGUS-M DIRECTIONAL. OVERCURRENT RELAY CASE SIZE E8, 5 CT,4 VT,16LEDS, 13 BINARY INP./14 BINARY OUTP. MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ USB FRONT PORT, RS485 REAR PORT IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION PLUS AUTORECLOSE (79) + (25) CHECK Auxiliary voltage: 24 - 250 V DC / 100-230 V AC Binary input threshold...
Product detailsAdd to RFQ
7SR2303-1AA12-0CA0 - Siemens
HIGH IMPEDANCE PROTECTION RELAY CIRCULATING CURRENT (4 POLE FUNCTIONALITY) E8 CASE, 4 CT, 19 LEDS, 19 BINARY INPUTS/ 16 BINARY OUTPUTS MEASURING INPUT: 1/5A, 50/60HZ 30 TO 220V DC AUXILLIARY, BINARY INPUT THRESHOLD 19V DC . USB FRONT PORT, RS485 REAR PORT PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) . PROTECTION FUNCTION: 3 PHASE HIGH...
Product detailsAdd to RFQ
7SR2302-1NA12-0CA0 - Siemens
HIGH IMPEDANCE PROTECTION RELAY CIRCULATING CURRENT (4 POLE FUNCTIONALITY) E6 CASE, 4 CT, 8 LEDS, 9 BINARY INPUTS/ 8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ Auxiliary voltage: 24 - 250 V DC / 100-230 V AC Binary input threshold 88 V DC (rated: 110-250 V DC) . USB FRONT PORT, RS485 REAR PORT PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND...
Product detailsAdd to RFQ
7SR2203-2MA77-0CA0 - Siemens
Argus-M Directional time-overcurrent protection E8 enclosure, 5 curr. trans., 4 volt. trans.,13 BI /14 BO,16 LEDs Measuring inputs: 1/5A, 63.5/110V, 50/60Hz Auxiliary voltage 24 - 250V DC / 100- 230V AC Threshold binary input: 19V DC USB interface at front, RS485 interface at rear, + electr. Ethernet RJ45 at rear Protocol: IEC 60870-5-103 and Modbus RTU and DNP 3.0 (adjustable)...
Product detailsAdd to RFQ
7SR2204-2NA77-0EA0 - Siemens
ARGUS-M DIRECTIONAL. OVERCURRENT RELAY CASE SIZE E8, 5 CT, 4 VT, 13 BINARY INP./14 BINARY OUTP. 8 LEDS + 6 KEYS MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ USB FRONT PORT, RS485 REAR PORT + REAR ELECTRICAL ETHERNET RJ45 IEC 60870-5-103, MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) AND IEC 61850 PROTECTION FUNCTION: STANDARD VERSION PLUS AUTORECLOSE (79) +...
Product detailsAdd to RFQ
7SR2203-2NA11-0CA0 - Siemens
ARGUS-M DIRECTIONAL. OVERCURRENT RELAY CASE SIZE E8, 5 CT,4 VT,16LEDS, 13 BINARY INP./14 BINARY OUTP. MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ USB FRONT PORT, RS485 REAR PORT IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION Auxiliary voltage: 24 - 250 V DC / 100-230 V AC Binary input threshold 88 V DC (rated: 110-250 V...
Product detailsAdd to RFQ
7SR2302-1NA87-0CA0 - Siemens
HIGH IMPEDANCE PROTECTION RELAY CIRCULATING CURRENT (4 POLE FUNCTIONALITY) E6 CASE, 4 CT, 8 LEDS, 9 BINARY INPUTS/ 8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ Auxiliary voltage: 24 - 250 V DC / 100-230 V AC Binary input threshold 88 V DC (rated: 110-250 V DC) . USB FRONT PORT, RS485 REAR PORT + REAR OPTICAL ETHERNET DUPLEX PROTOCOL: IEC...
Product detailsAdd to RFQ
7SR2202-2NA12-0CA0 - Siemens
ARGUS-M DIRECTIONAL. OVERCURRENT RELAY CASE SIZE E6, 5 CT,4 VT,8 LEDS, 3 BINARY INPUTS/6 BINARY OUTP. MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ USB FRONT PORT, RS485 REAR PORT IEC 60870-5-103, MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION Auxiliary voltage: 24 - 250 V DC / 100-230 V AC Binary input threshold 88 V DC...
Product detailsAdd to RFQ
7SR2203-2MA87-0CA0 - Siemens
Argus-M Directional time-overcurrent protection E8 enclosure, 5 curr. trans., 4 volt. trans.,13 BI /14 BO,16 LEDs Measuring inputs: 1/5A, 63.5/110V, 50/60Hz Auxiliary voltage 24 - 250V DC / 100- 230V AC Threshold binary input: 19V DC USB interface at front, RS485 interface at rear, + opt. Ethernet Duplex at rear Protocol: IEC 60870-5-103 and Modbus RTU and DNP 3.0 (adjustable)...