[siemens_summary]
[catalog_children]
[catalog_search_products]

Capacitance transmitters ⍾ Page 13

Product detailsAdd to RFQ
7ML5651-3DA00-0CB0-Z Y15 - Siemens
Pointek CLS300 RF Capacitance point level switch, cable design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Cable extension options to 25 m (82.02 ft), adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: G 1 1/2"(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Probe Length: (Lengths from flange face) Extended cable, 3000...
Product detailsAdd to RFQ
7ML5651-1DF00-0KB0-Z Y01 - Siemens
Pointek CLS300 RF Capacitance point level switch, cable design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Cable extension options to 25 m (82.02 ft), adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Add order code...
Product detailsAdd to RFQ
7ML5651-3DA00-0HB0 - Siemens
Pointek CLS300 RF Capacitance point level switch, cable design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Cable extension options to 25 m (82.02 ft), adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: G 1 1/2"(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Probe Length: (Lengths from flange face) Extended cable, 3000...
Product detailsAdd to RFQ
7ML5651-1DA00-0JB0 - Siemens
Pointek CLS300 RF Capacitance point level switch, cable design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Cable extension options to 25 m (82.02 ft), adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe Length: (Lengths from flange face) Extended cable, 3000...
Product detailsAdd to RFQ
7ML5650-6ED10-0JB0 - Siemens
Pointek CLS300 RF Capacitance point level switch, rod design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 50, PN 16 Probe length: (length from flange face) (threaded...
Product detailsAdd to RFQ
7ML5651-1DB00-0CB0 - Siemens
Pointek CLS300 - Standard - Cable Version with Threaded or Flanged process connection: Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam and interfaces in demanding conditions where high pressure and temperatures are present. Process Connection: R 1 1/2" (BSPT), EN 10226/PT (JIS-T), JIS B 0203 Probe...
Product detailsAdd to RFQ
7ML5651-5DA00-0HA0 - Siemens
Pointek CLS300 RF Capacitance point level switch, cable design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Cable extension options to 25 m (82.02 ft), adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L stainless steel, raised face: 1 1/2" ASME, 150 lb Probe Length: (Lengths from flange face) Extended...
Product detailsAdd to RFQ
7ML5651-3DA00-0CB0 - Siemens
Pointek CLS300 RF Capacitance point level switch, cable design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Cable extension options to 25 m (82.02 ft), adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: G 1 1/2"(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Probe Length: (Lengths from flange face) Extended cable, 3000...
Product detailsAdd to RFQ
7ML5650-6GD10-0FA0 - Siemens
Pointek CLS300 RF Capacitance point level switch, rod design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Welded flange, 316L (1.4404) stainless steel, Type A flat faced: DN 80, PN 16 Probe length: (length from flange face) (threaded...
Product detailsAdd to RFQ
7ML5651-0DA00-0HA0 - Siemens
Pointek CLS300 RF Capacitance point level switch, cable design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Cable extension options to 25 m (82.02 ft), adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/2" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended cable, 3000 mm (118.11"), length can...
Product detailsAdd to RFQ
7ML5651-0CF00-0FA0-Z Y01 - Siemens
Pointek CLS300 RF Capacitance point level switch, cable design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Cable extension options to 25 m (82.02 ft), adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Add order code Y01 and plain text:...
Product detailsAdd to RFQ
7ML5651-0CA00-0FA0 - Siemens
Pointek CLS300 RF Capacitance point level switch, cable design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Cable extension options to 25 m (82.02 ft), adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: 1 1/4" NPT (Taper), ANSI/ASME B1.20.1 Probe Length: (Lengths from flange face) Extended cable, 3000 mm (118.11"), length can...