Capacitance transmitters ⍾ Page 18

Product detailsAdd to RFQ
7ML5650-0AA00-0JB0 - Siemens
Pointek CLS300 RF Capacitance point level switch, rod design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Threaded, 316L (1.4404) stainless steel 3/4" NPT (Taper), ANSI/ASME B1.20.1 Probe length: (length from flange face) (threaded lengths include process thread)...
Product detailsAdd to RFQ
7ML5650-0AA00-0HA0 - Siemens
Pointek CLS300 RF Capacitance point level switch, rod design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Threaded, 316L (1.4404) stainless steel 3/4" NPT (Taper), ANSI/ASME B1.20.1 Probe length: (length from flange face) (threaded lengths include process thread)...
Product detailsAdd to RFQ
7ML5642-8CN01-1BB0-Z Y01 - Siemens
Pointek CLS200 - Digital - Rod with Sanitary process connection. Versatile inverse frequency shift capacitance level switch with optional process connection choices and configurable output, ideal for detection of liquids, solids, slurries, foam and interfaces Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from flange face) Add order code Y01 and plain text: "Insertion...
Product detailsAdd to RFQ
7ML5642-8CD01-1BB0-Z Y01 - Siemens
Pointek CLS200 - Digital - Rod with Sanitary process connection. Versatile inverse frequency shift capacitance level switch with optional process connection choices and configurable output, ideal for detection of liquids, solids, slurries, foam and interfaces Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from flange face) Extended rod, 500 mm (19.69") Thermal Isolator: Without...
Product detailsAdd to RFQ
7ML5631-1AA00-0KB0 - Siemens
Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 3/4" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face)...
Product detailsAdd to RFQ
7ML5643-3AG01-0LD0 - Siemens
Pointek CLS200 RF Capacitance point level switch, digital, sliding coupling design. Detects level and interface in liquids, solids, slurries, and, foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. With display and digital communications. Process Connection: G 3/4" (BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202 Probe length: (length from flange...
Product detailsAdd to RFQ
7ML5650-0AA10-0HA0 - Siemens
Pointek CLS300 RF Capacitance point level switch, rod design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Threaded, 316L (1.4404) stainless steel 3/4" NPT (Taper), ANSI/ASME B1.20.1 Probe length: (length from flange face) (threaded lengths include process thread)...
Product detailsAdd to RFQ
7ML5650-0AA00-0HB0 - Siemens
Pointek CLS300 RF Capacitance point level switch, rod design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. Process Connection: Threaded, 316L (1.4404) stainless steel 3/4" NPT (Taper), ANSI/ASME B1.20.1 Probe length: (length from flange face) (threaded lengths include process thread)...
Product detailsAdd to RFQ
7ML5631-0DC00-0DA0-Z Y01 - Siemens
Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: 1 1/2" NPT ((Taper), ANSI/ASME B1.20.1) Probe length: (length from flange face) (threaded lengths include...
Product detailsAdd to RFQ
7ML5631-1AA00-0HB0 - Siemens
Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 3/4" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face)...
Product detailsAdd to RFQ
7ML5640-0AD10-0EB0 - Siemens
Pointek CLS200 - Digital - Rod Version with Threaded or Flanged process connection: Versatile inverse frequency shift capacitance level switch with optional process connection choices and configurable output, ideal for detection of liquids, solids,slurries, foam and interfaces Process Connection: Threaded, 316L (1.4404) stainless steel: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Probe length: (length from flange face) (threaded lengths include process thread)...
Product detailsAdd to RFQ
7ML5640-0AB10-0KB0 - Siemens
Pointek CLS200 RF Capacitance point level switch, digital, rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. With display and digital communications. Process Connection: Threaded, 316L (1.4404) stainless steel: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Probe length: (length from flange face)...