7MB2123-0DM00-1NF1 - Siemens
2-Kanal ULTRAMAT 6, 19"Built-In gas analyzer cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CH4 Smallest measuring range: 0 to 5000 vpm, largest measuring range: 0 to 50000 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz...
Product detailsAdd to RFQ
7MB2123-0AT00-1CT1 - Siemens
2-Kanal ULTRAMAT 6, 19"Built-In gas analyzer cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 5 %, largest measuring range: 0 to 50 % Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz...
Product detailsAdd to RFQ
7MB2123-0AL03-1PG2 - Siemens
2-Kanal ULTRAMAT6 gas analyzer two-channel 19" rack unit for installation in cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 5000 vpm, largest measuring range: 0 to 15000 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type AUTOCAL function with 8 additional...
Product detailsAdd to RFQ
7MB2123-0AB27-1CA1-Z Y02 - Siemens
2-Kanal ULTRAMAT 6, 19"Built-In gas analyzer cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 10 vpm, largest measuring range: 0 to 200 vpm With sample gas monitoring, internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type AUTOCAL function with 8 additional digital...
Product detailsAdd to RFQ
7MB2123-0AQ20-1DN1 - Siemens
2-Kanal ULTRAMAT6 gas analyzer two-channel 19" rack unit for installation in cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 3 %, largest measuring range: 0 to 10 % With sample gas monitoring, internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type Without...
Product detailsAdd to RFQ
7MB2123-0AP00-1DP1-Z Y11 - Siemens
2-Kanal ULTRAMAT 6, 19"Built-In gas analyzer cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 1 %, largest measuring range: 0 to 10 % Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz...
Product detailsAdd to RFQ
7MB2121-1CA67-1AA1 - Siemens
ULTRAMAT 6E gas analyzer single-channel 19" unit for installation in cabinets Gas connection: stub with 1/4 " od Measured component: CO2 Smallest measuring range: 0 to 5 vpm Largest measuring range 0 to 100 vpm range code 10 Internal gas path: stainless steel tubing sample cell (lining): aluminium reference part of meas.chamber: non-flowing-reference-side with additional electronics with 8 binary inputs...
Product detailsAdd to RFQ
7MB2123-0AM00-1DK1-Z Y11 - Siemens
2-Kanal ULTRAMAT6 gas analyzer two-channel 19" rack unit for installation in cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 5000 vpm, largest measuring range: 0 to 50000 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type Without 200 to 240 V...
Product detailsAdd to RFQ
7MB2123-0AB27-1CB1 - Siemens
ULTRAMAT 6 gas analyzer, two-channel 19" rack unit for installation in cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 10 vpm, largest measuring range: 0 to 200 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type AUTOCAL function with 8 additional...
Product detailsAdd to RFQ
7MB2123-0AL03-1PG1 - Siemens
2-Kanal ULTRAMAT 6, 19"Built-In gas analyzer cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 5000 vpm, largest measuring range: 0 to 15000 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type AUTOCAL function with 8 additional digital inputs/outputs each for channel...
Product detailsAdd to RFQ
7MB2121-1QP60-1AA1 - Siemens
ULTRAMAT 6 19" Built-In gas analyzer, single-channel 19" rack unit for installation in cabinets Pipe with 1/4" outer diameter NH3 Smallest measuring range: 0 to 1 %, largest measuring range: 0 to 10 %, Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC, 48 to 63...
Product detailsAdd to RFQ
7MB2121-1QN40-1AA1 - Siemens
ULTRAMAT 6 19" Built-In gas analyzer, single-channel 19" rack unit for installation in cabinets Pipe with 1/4" outer diameter NH3 Smallest measuring range: 0 to 1 %, largest measuring range: 0 to 3 %, Internal gas path: Pipe made of titanium, sample chamber (lining): Tantalum, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz ....