[siemens_summary]
[catalog_children]
[catalog_search_products]

Continuous gas analyzers ⍾ Page 52

Product detailsAdd to RFQ
7MB2023-0EA00-1AM1-Z Y11 - Siemens
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 Internal gas path (both channels): hose made of FKM (Viton), sample chamber (lining, ULTRAMAT channel): Aluminium, reference chamber...
Product detailsAdd to RFQ
7MB2023-0EA00-1AP1 - Siemens
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 Internal gas path (both channels): hose made of FKM (Viton), sample chamber (lining, ULTRAMAT channel): Aluminium, reference chamber...
Product detailsAdd to RFQ
7MB2021-1AA20-1AF1-Z Y02 - Siemens
OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets Pipe with 1/4" outer diameter 0.5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 Pipe made of stainless steel, mat. no. 1.4571 , 200 to 240 V AC, 48 to 63 Hz Without AUTOCAL function with 8 digital inputs/outputs, PROFIBUS DP interface...
Product detailsAdd to RFQ
7MB2023-0AA13-1ND1-Z Y12 - Siemens
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 0.5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 Internal gas path (both channels): hose made of FKM (Viton), sample chamber (lining, ULTRAMAT channel): Aluminium, reference chamber...
Product detailsAdd to RFQ
7MB2023-0EA00-1AM1 - Siemens
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 Internal gas path (both channels): hose made of FKM (Viton), sample chamber (lining, ULTRAMAT channel): Aluminium, reference chamber...
Product detailsAdd to RFQ
7MB2023-0EA00-1AD1 - Siemens
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 Internal gas path (both channels): hose made of FKM (Viton), sample chamber (lining, ULTRAMAT channel): Aluminium, reference chamber...
Product detailsAdd to RFQ
7MB2021-0CA00-1BA1 - Siemens
OXYMAT 6, 19" Built-In rack unit for installation in cabinets Pipe with 6 mm outer diameter 2% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 Hose made of FKM (Viton) , 200 to 240 V AC, 48 to 63 Hz Reference gas only Without English
Product detailsAdd to RFQ
7MB2023-0CB40-0NR1 - Siemens
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 2% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of tantalum Internal gas path (both channels): pipe made of titanium, sample chamber (lining, ULTRAMAT channel): Tantalum, reference chamber (flow-type, ULTRAMAT channel): non-flow-type Without...
Product detailsAdd to RFQ
7MB2023-0AA00-1CE1 - Siemens
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 0.5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 Internal gas path (both channels): hose made of FKM (Viton), sample chamber (lining, ULTRAMAT channel): Aluminium, reference chamber...
Product detailsAdd to RFQ
7MB2023-0EA00-0AJ1 - Siemens
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 Internal gas path (both channels): hose made of FKM (Viton), sample chamber (lining, ULTRAMAT channel): Aluminium, reference chamber...
Product detailsAdd to RFQ
7MB2021-0EB10-1BB1 - Siemens
OXYMAT 6, 19" Built-In rack unit for installation in cabinets Pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of tantalum Pipe made of titanium , 200 to 240 V AC, 48 to 63 Hz Reference gas only AUTOCAL function with 8 additional digital inputs/outputs English
Product detailsAdd to RFQ
7MB2021-0DA00-1DA4 - Siemens
OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets Pipe with 6 mm outer diameter 2% reference gas pressure 100 hPa (external pump) Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 Hose made of FKM (Viton) , 200 to 240 V AC, 48 to 63 Hz Sample gas only sample gas Without Italian