[siemens_summary]
[catalog_children]
[catalog_search_products]

Current and voltage measurement ⍾ Page 3

Product detailsAdd to RFQ
PACT RCP-4000A-1A-D95 - Phoenix Contact
Current transformer - PACT RCP-4000A-1A-D95 - 2904921; Set consisting of a 1 A measuring transducer and a Rogowski coil with signal line. Length of Rogowski coil: 300 mm, diameter: 95 mm. Length of signal line: 3 m. The Rogowski coil measures the AC current of busbars and power lines.
Product detailsAdd to RFQ
PACT RCP-D190 - Phoenix Contact
Coil - PACT RCP-D190 - 2904892; 600 mm long Rogowski coil. The measuring coil diameter when installed is 190 mm. The Rogowski coil is used for AC current measurement for busbars and power lines.
Product detailsAdd to RFQ
PACT RCP-CLAMP - Phoenix Contact
Holder - PACT RCP-CLAMP - 2904895; The optional holding device ensures the Rogowski coil is securely seated on busbars with a thickness of 10 ... 15 mm. During installation, the coil housing is pushed onto the flange of the holding device and snaps in automatically.
Product detailsAdd to RFQ
PACT RCP-D140 - Phoenix Contact
Coil - PACT RCP-D140 - 2904891; 450 mm long Rogowski coil. The measuring coil diameter when installed is 140 mm. The Rogowski coil is used for AC current measurement for busbars and power lines.
Product detailsAdd to RFQ
PACT RCP-4000A-1A - Phoenix Contact
Measuring transducer - PACT RCP-4000A-1A - 2902990; This is an individual product; please order the complete set. The measuring transducer processes the mV signal of the upstream Rogowski coil. The measuring transducer has 8 current measuring ranges (100 A ... 4000 A AC) which can be set; max. output current of 1 A AC.
Product detailsAdd to RFQ
PACT V1-21-44-100-5A-05-15 - Phoenix Contact
Current transformer - PACT V1-21-44-100-5A-05-15 - 2902548; Bus-bar current transformer, 100 A AC primary current; 5 A AC secondary current; accuracy class 0.5; 1.5 VA rated power
Product detailsAdd to RFQ
MCR-SL-S- 16-SP- 24 - Phoenix Contact
Current monitoring - MCR-SL-S- 16-SP- 24 - 2864464; MCR contactor, for sinusoidal alternating currents 0 ... 16 A AC/ 1 PDT
Product detailsAdd to RFQ
MCR-S-1-5-UI-DCI-NC - Phoenix Contact
Current transducers - MCR-S-1/5-UI-DCI-NC - 2814715; MCR current transducer, programmable and configurable, for measuring direct, alternating and distorted currents, input current 0...0.2 to 0...11 A, unconfigured
Product detailsAdd to RFQ
MCR-S10-50-UI-SW-DCI-NC - Phoenix Contact
Current transducers - MCR-S10/50-UI-SW-DCI-NC - 2814744; MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, with relay and transistor output, input current 0...10 to 0...50 A, unconfigured
Product detailsAdd to RFQ
MCR-S10-50-UI-DCI-NC - Phoenix Contact
Current transducers - MCR-S10/50-UI-DCI-NC - 2814728; MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, input current 0...10 to 0...50 A, unconfigured
Product detailsAdd to RFQ
MCR-S-1-5-UI-SW-DCI-NC - Phoenix Contact
Current transducers - MCR-S-1/5-UI-SW-DCI-NC - 2814731; MCR current transducer, programmable and configurable, for measuring direct, alternating and distorted currents, with relay and transistor output, input current 0 ... 0.2 A to 0 ... 11 A, unconfigured
Product detailsAdd to RFQ
MCR-SLP-1-5-UI-0 - Phoenix Contact
Current transducers - MCR-SLP-1/5-UI-0 - 2814359; MCR passive current measuring transducer, for sinusoidal alternating currents 0..1 A AC/0..5 A AC, without switching output, output signal 0..10 V/0..20 mA