[siemens_summary]
[catalog_children]
[catalog_search_products]
DBS36E-S3P / DBS36

DBS36E-S3P / DBS36

Items 1 - 12 of 15 from SICK ⍾ Last modified Sep 3, 2025

DBS36E-S3P / DBS36 ⍾ Page 1

Product detailsAdd to RFQ
DBS36E-S3PM01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS36E-S3PM00360 - Sick
Performance: Pulses per revolution: 360; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS36E-S3PP00500 - Sick
DBS36. Electrical interface: 4.5 V ... 5.5 V, open collector, Cable, 8-pin with male connector M12, universal, 0.5 m.
Product detailsAdd to RFQ
DBS36E-S3PN00100 - Sick
Performance: Pulses per revolution: 100; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS36E-S3PL02000 - Sick
Performance: Pulses per revolution: 2,000; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS36E-S3PK02048 - Sick
DBS36. Electrical interface: 4.5 V ... 5.5 V, open collector, Cable, 8-pin with male connector M12, universal, 1.5 m.
Product detailsAdd to RFQ
DBS36E-S3PK00600 - Sick
Performance: Pulses per revolution: 600; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS36E-S3PK00360 - Sick
Performance: Pulses per revolution: 360; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS36E-S3PL00200 - Sick
DBS36. Electrical interface: 4.5 V ... 5.5 V, open collector, Cable, 8-pin with male connector M12, universal, 3 m.
Product detailsAdd to RFQ
DBS36E-S3PL00500 - Sick
Performance: Pulses per revolution: 500; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS36E-S3PK02000 - Sick
Performance: Pulses per revolution: 2,000; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS36E-S3PK01000 - Sick
DBS36. Electrical interface: 4.5 V ... 5.5 V, open collector, Cable, 8-pin with male connector M12, universal, 1.5 m.