[siemens_summary]
[catalog_children]
[catalog_search_products]

DBS50 ⍾ Page 2

Product detailsAdd to RFQ
DBS50E-S5RK00360 - Sick
Performance: Pulses per revolution: 360; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS50E-S5RK00300 - Sick
Performance: Pulses per revolution: 300; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS50E-S5RK00600 - Sick
Performance: Pulses per revolution: 600; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS50E-S5RL01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS50E-S5RK01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS50E-S5RK01000 - Sick
Performance: Pulses per revolution: 1,000; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS50E-S5GN01000 - Sick
Performance: Pulses per revolution: 1,000; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DBS50E-S5GL00600 - Sick
Performance: Pulses per revolution: 600; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DBS50E-S5GM00100 - Sick
Performance: Pulses per revolution: 100; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DBS50E-S5RL00360 - Sick
Performance: Pulses per revolution: 360; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS50E-S5GM01000 - Sick
Performance: Pulses per revolution: 1,000; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DBS50E-S5GM00360 - Sick
Performance: Pulses per revolution: 360; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...