DBS60E-S4FC01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Number of signal channels: 6-channel; Initialization time: < 5 ms 2); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EL01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EL00125 - Sick
Performance: Pulses per revolution: 125; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4FC02500 - Sick
Performance: Pulses per revolution: 2,500; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Number of signal channels: 6-channel; Initialization time: < 5 ms 2); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EP00200 - Sick
Performance: Pulses per revolution: 200; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EP02048 - Sick
Performance: Pulses per revolution: 2,048; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EL02000 - Sick
Performance: Pulses per revolution: 2,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EL05000 - Sick
Performance: Pulses per revolution: 5,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EM05000 - Sick
Performance: Pulses per revolution: 5,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EN01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EN05000 - Sick
Performance: Pulses per revolution: 5,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EN02500 - Sick
Performance: Pulses per revolution: 2,500; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...