[siemens_summary]
[catalog_children]
[catalog_search_products]
DBS60E-S4 / DBS60

DBS60E-S4 / DBS60

Items 37 - 48 of 120 from SICK ⍾ Last modified Sep 3, 2025

DBS60E-S4 / DBS60 ⍾ Page 4

Product detailsAdd to RFQ
DBS60E-S4EK03600 - Sick
Performance: Pulses per revolution: 3,600; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EK04096 - Sick
Performance: Pulses per revolution: 4,096; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EK05000 - Sick
Performance: Pulses per revolution: 5,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EN02000 - Sick
Performance: Pulses per revolution: 2,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EK00100 - Sick
Performance: Pulses per revolution: 100; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EK03000 - Sick
Performance: Pulses per revolution: 3,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EK00500 - Sick
Performance: Pulses per revolution: 500; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EK02500 - Sick
Performance: Pulses per revolution: 2,500; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EK01000 - Sick
Performance: Pulses per revolution: 1,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EK00360 - Sick
Performance: Pulses per revolution: 360; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EK02048 - Sick
Performance: Pulses per revolution: 2,048; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EK01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...