[siemens_summary]
[catalog_children]
[catalog_search_products]
DBV50

DBV50

Items 37 - 48 of 75 from SICK ⍾ Last modified Sep 3, 2025

DBV50 ⍾ Page 4

Product detailsAdd to RFQ
DBV50E-22ELA1000 - Sick
Performance: Pulses per revolution: 1,000; Resolution in pulses/mm: 5; Measuring increment (resolution in mm/pulse): 0.2, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22ELA0500 - Sick
Performance: Pulses per revolution: 500; Resolution in pulses/mm: 2.5; Measuring increment (resolution in mm/pulse): 0.4, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22ELA0010 - Sick
Performance: Pulses per revolution: 10; Resolution in pulses/mm: 0.05; Measuring increment (resolution in mm/pulse): 20, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22EMA2500 - Sick
Performance: Pulses per revolution: 2,500; Resolution in pulses/mm: 12.5; Measuring increment (resolution in mm/pulse): 0.08, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22EKA2000 - Sick
Performance: Pulses per revolution: 2,000; Resolution in pulses/mm: 10; Measuring increment (resolution in mm/pulse): 0.1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22EKA0500 - Sick
Performance: Pulses per revolution: 500; Resolution in pulses/mm: 2.5; Measuring increment (resolution in mm/pulse): 0.4, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22EKA1000 - Sick
Performance: Pulses per revolution: 1,000; Resolution in pulses/mm: 5; Measuring increment (resolution in mm/pulse): 0.2, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22ELA2000 - Sick
Performance: Pulses per revolution: 2,000; Resolution in pulses/mm: 10; Measuring increment (resolution in mm/pulse): 0.1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22EKA0020 - Sick
Performance: Pulses per revolution: 20; Resolution in pulses/mm: 0.01; Measuring increment (resolution in mm/pulse): 10, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22CQA2500 - Sick
Performance: Pulses per revolution: 2,500; Resolution in pulses/mm: 12.5; Measuring increment (resolution in mm/pulse): 0.08, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22CPA2500 - Sick
Performance: Pulses per revolution: 2,500; Resolution in pulses/mm: 12.5; Measuring increment (resolution in mm/pulse): 0.08, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22EKB0200 - Sick
Performance: Pulses per revolution: 200; Resolution in pulses/mm: 1; Measuring increment (resolution in mm/pulse): 1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...