Product detailsAdd to RFQ
C4P-EA21010A001000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 2,100 mm; Response time: 22 ms (Uncoded)51 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverSystem plug 1000Test rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA21010A00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 2,100 mm; Response time: 22 ms (Uncoded)51 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters:...
Product detailsAdd to RFQ
C4P-EA18031C00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 1,800 mm; Response time: 13 ms (Uncoded)24 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters:...
Product detailsAdd to RFQ
C4P-EA18030A001300 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 1,800 mm; Response time: 13 ms (Uncoded)24 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverSystem plug 1300Test rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA18031D00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 1,800 mm; Response time: 13 ms (Uncoded)24 ms (code 1 or code 2); Synchronization: Optical synchronisation; End cap with integrated LED: ✔; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA19531C00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 1,950 mm; Response time: 14 ms (Uncoded)25 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters:...
Product detailsAdd to RFQ
C4P-EA19511C00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 1,950 mm; Response time: 21 ms (Uncoded)48 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters:...
Product detailsAdd to RFQ
C4P-EA19510A001000 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 1,950 mm; Response time: 21 ms (Uncoded)48 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverSystem plug 1000Test rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA19510A00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 1,950 mm; Response time: 21 ms (Uncoded)48 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters:...
Product detailsAdd to RFQ
C4P-EA1803S001 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 1,800 mm; Response time: 13 ms (Uncoded)24 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Receiver with preassembled system plug M12, 5-pinTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting...
Product detailsAdd to RFQ
C4P-EA19510A001100 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 1,950 mm; Response time: 21 ms (Uncoded)48 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverSystem plug 1100Test rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C4P-EA19511D00 - Sick
Features: Application: Normal industrial environment; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 1,950 mm; Response time: 21 ms (Uncoded)48 ms (code 1 or code 2); Synchronization: Optical synchronisation; End cap with integrated LED: ✔; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...