[siemens_summary]
[catalog_children]
[catalog_search_products]
deTec

deTec

Items 721 - 732 of 864 from SICK ⍾ Last modified Sep 3, 2025

deTec ⍾ Page 61

Product detailsAdd to RFQ
C2C-SG21030A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Sender; Compatible receiver: 1221109; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 2,100 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance...
Product detailsAdd to RFQ
C2C-SV09030A10000 - Sick
Features: Application: Machines with strong shock or vibration loads; System part: Sender; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 900 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance level: PL c (ISO 13849-1);...
Product detailsAdd to RFQ
C2C-SV03030A10000 - Sick
Features: Application: Machines with strong shock or vibration loads; System part: Sender; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 300 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance level: PL c (ISO 13849-1);...
Product detailsAdd to RFQ
C2C-SV06030C10000 - Sick
Features: Application: Machines with strong shock or vibration loads; System part: Sender; Resolution: 30 mm; Scanning range: 6 m; Protective field height: 600 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance level: PL c (ISO 13849-1);...
Product detailsAdd to RFQ
C2C-SV03030C10000 - Sick
Features: Application: Machines with strong shock or vibration loads; System part: Sender; Resolution: 30 mm; Scanning range: 6 m; Protective field height: 300 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance level: PL c (ISO 13849-1);...
Product detailsAdd to RFQ
C2C-SG13510A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Sender; Compatible receiver: 1220507; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,350 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance...
Product detailsAdd to RFQ
C2C-SG12030A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Sender; Compatible receiver: 1220528; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,200 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance...
Product detailsAdd to RFQ
C2C-SG21010A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Sender; Compatible receiver: 1221107; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 2,100 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance...
Product detailsAdd to RFQ
C2C-SV04530C10000 - Sick
Features: Application: Machines with strong shock or vibration loads; System part: Sender; Resolution: 30 mm; Scanning range: 6 m; Protective field height: 450 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance level: PL c (ISO 13849-1);...
Product detailsAdd to RFQ
C2C-SG19530A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Sender; Compatible receiver: 1221101; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,950 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance...
Product detailsAdd to RFQ
C2C-SG15010A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Sender; Compatible receiver: 1220508; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,500 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance...
Product detailsAdd to RFQ
C2C-SG18030A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Sender; Compatible receiver: 1220532; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,800 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance...