Items 781 - 792 of 864 from SICK ⍾ Last modified Sep 3, 2025

deTec ⍾ Page 66

Product detailsAdd to RFQ
C2C-EV15030B10000 - Sick
Features: Application: Machines with strong shock or vibration loads; System part: Receiver; Resolution: 30 mm; Scanning range: 3.8 m; Protective field height: 1,500 mm; Response time: 13 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2...
Product detailsAdd to RFQ
C2C-SA09030A10000 - Sick
Features: Application: Normal industrial environment; System part: Sender; Compatible receiver: 1213209; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 900 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance level: PL c (ISO 13849-1); PFHD...
Product detailsAdd to RFQ
C2C-SA12010A10000 - Sick
Features: Application: Normal industrial environment; System part: Sender; Compatible receiver: 1213199; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,200 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance level: PL c (ISO 13849-1); PFHD...
Product detailsAdd to RFQ
C2C-SA07510A10000 - Sick
Features: Application: Normal industrial environment; System part: Sender; Compatible receiver: 1213194; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 750 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance level: PL c (ISO 13849-1); PFHD...
Product detailsAdd to RFQ
C2C-SA06010A10000 - Sick
Features: Application: Normal industrial environment; System part: Sender; Compatible receiver: 1213192; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 600 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance level: PL c (ISO 13849-1); PFHD...
Product detailsAdd to RFQ
C2C-EV09030A10000 - Sick
Features: Application: Machines with strong shock or vibration loads; System part: Receiver; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 900 mm; Response time: 11 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2...
Product detailsAdd to RFQ
C2C-EV09030B10000 - Sick
Features: Application: Machines with strong shock or vibration loads; System part: Receiver; Resolution: 30 mm; Scanning range: 3.8 m; Protective field height: 900 mm; Response time: 11 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2...
Product detailsAdd to RFQ
C2C-EV06030C10000 - Sick
Features: Application: Machines with strong shock or vibration loads; System part: Receiver; Resolution: 30 mm; Scanning range: 6 m; Protective field height: 600 mm; Response time: 10 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2...
Product detailsAdd to RFQ
C2C-SA10530A10000 - Sick
Features: Application: Normal industrial environment; System part: Sender; Compatible receiver: 1213211; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,050 mm; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance level: PL c (ISO 13849-1); PFHD...
Product detailsAdd to RFQ
C2C-EV04530C10000 - Sick
Features: Application: Machines with strong shock or vibration loads; System part: Receiver; Resolution: 30 mm; Scanning range: 6 m; Protective field height: 450 mm; Response time: 10 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2...
Product detailsAdd to RFQ
C2C-EV04530B10000 - Sick
Features: Application: Machines with strong shock or vibration loads; System part: Receiver; Resolution: 30 mm; Scanning range: 3.8 m; Protective field height: 450 mm; Response time: 10 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2...
Product detailsAdd to RFQ
C2C-EV04530A10000 - Sick
Features: Application: Machines with strong shock or vibration loads; System part: Receiver; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 450 mm; Response time: 10 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2...