[siemens_summary]
[catalog_children]
[catalog_search_products]
deTec

deTec

Items 805 - 816 of 864 from SICK ⍾ Last modified Sep 3, 2025

deTec ⍾ Page 68

Product detailsAdd to RFQ
C2C-EG15010A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Compatible sender: 1220497; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,500 mm; Response time: 18 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C2C-EG21010A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Compatible sender: 1221106; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 2,100 mm; Response time: 22 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C2C-EG19530A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Compatible sender: 1221100; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,950 mm; Response time: 14 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C2C-EG16530A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Compatible sender: 1220520; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,650 mm; Response time: 13 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C2C-EG18010A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Compatible sender: 1220499; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,800 mm; Response time: 20 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C2C-EG12010A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Compatible sender: 1220495; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 1,200 mm; Response time: 16 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C2C-EG03030A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Compatible sender: 1220511; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 300 mm; Response time: 10 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C2C-EG10530A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Compatible sender: 1220516; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,050 mm; Response time: 11 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C2C-EG18030A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Compatible sender: 1220521; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 1,800 mm; Response time: 13 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C2C-EG09030A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Compatible sender: 1220515; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 900 mm; Response time: 11 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C2C-EG06030A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Compatible sender: 1220513; Resolution: 30 mm; Scanning range: 15 m; Protective field height: 600 mm; Response time: 10 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...
Product detailsAdd to RFQ
C2C-EG09010A10000 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Compatible sender: 1220493; Resolution: 14 mm; Scanning range: 10 m; Protective field height: 900 mm; Response time: 14 ms; No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting instructionsOperating instructions for download;...