[siemens_summary]
[catalog_children]
[catalog_search_products]
deTem

deTem

Items 25 - 36 of 46 from SICK ⍾ Last modified Sep 4, 2025

deTem ⍾ Page 3

Product detailsAdd to RFQ
M2C-SX0430LA10 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; Functional principle: Sender/receiver system; System part: Sender; Scanning range: 17 m; Dimension of the light pathTypical0.5 m ... 17 m: Dimension of the light path; Number of beams: 4; Beam separation: 300 mm; Response...
Product detailsAdd to RFQ
M2C-SX0430HA10 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; Functional principle: Sender/receiver system; System part: Sender; Scanning range: 90 m; Dimension of the light pathTypical10 m ... 90 m: Dimension of the light path; Number of beams: 4; Beam separation: 300 mm; Response...
Product detailsAdd to RFQ
M2C-SX0340HA10 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; Functional principle: Sender/receiver system; System part: Sender; Scanning range: 90 m; Dimension of the light pathTypical10 m ... 90 m: Dimension of the light path; Number of beams: 3; Beam separation: 400 mm; Response...
Product detailsAdd to RFQ
M2C-SA0430LA10 - Sick
Features: Application: Normal industrial environment; Functional principle: Sender/receiver system; System part: Sender; Scanning range: 17 m; Dimension of the light pathMinimum0.5 m ... 15 mTypical0.5 m ... 17 m: Dimension of the light path; Number of beams: 4; Beam separation: 300 mm; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC...
Product detailsAdd to RFQ
M2C-SX0340LA10 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; Functional principle: Sender/receiver system; System part: Sender; Scanning range: 17 m; Dimension of the light pathTypical0.5 m ... 17 m: Dimension of the light path; Number of beams: 3; Beam separation: 400 mm; Response...
Product detailsAdd to RFQ
M2C-SA0430HA10 - Sick
Features: Application: Normal industrial environment; Functional principle: Sender/receiver system; System part: Sender; Scanning range: 90 m; Dimension of the light pathMinimum10 m ... 70 mTypical10 m ... 90 m: Dimension of the light path; Number of beams: 4; Beam separation: 300 mm; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC...
Product detailsAdd to RFQ
M2C-SA0250LA10 - Sick
Features: Application: Normal industrial environment; Functional principle: Sender/receiver system; System part: Sender; Scanning range: 17 m; Dimension of the light pathMinimum0.5 m ... 15 mTypical0.5 m ... 17 m: Dimension of the light path; Number of beams: 2; Beam separation: 500 mm; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC...
Product detailsAdd to RFQ
M2C-SA0340LA10 - Sick
Features: Application: Normal industrial environment; Functional principle: Sender/receiver system; System part: Sender; Scanning range: 17 m; Dimension of the light pathMinimum0.5 m ... 15 mTypical0.5 m ... 17 m: Dimension of the light path; Number of beams: 3; Beam separation: 400 mm; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC...
Product detailsAdd to RFQ
M2C-EB04300A10 - Sick
Features: Application: Areas with high pressure cleaning (hygiene, food); Functional principle: Sender/receiver system; System part: Receiver; Scanning range category: Low scanning range; Scanning range: 15.5 m; Dimension of the light pathMinimum0.5 m ... 12.5 mTypical0.5 m ... 15.5 m: Dimension of the light path; Number of beams: 4; Beam separation: 300 mm; Response time: 20 ms; Synchronization: Optical synchronisation; Items...
Product detailsAdd to RFQ
M2C-EA03400A10 - Sick
Features: Application: Normal industrial environment; Functional principle: Sender/receiver system; System part: Receiver; Number of beams: 3; Beam separation: 400 mm; Response time: 20 ms; Synchronization: Optical synchronisation; Items supplied: ReceiverSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance level: PL c (ISO...
Product detailsAdd to RFQ
M2C-EA04300A10 - Sick
Features: Application: Normal industrial environment; Functional principle: Sender/receiver system; System part: Receiver; Number of beams: 4; Beam separation: 300 mm; Response time: 20 ms; Synchronization: Optical synchronisation; Items supplied: ReceiverSafety instructionMounting instructionsOperating instructions for download; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (IEC 62061); Category: Category 2 (ISO 13849-1); Performance level: PL c (ISO...
Product detailsAdd to RFQ
M2C-SA0340HA10 - Sick
Features: Application: Normal industrial environment; Functional principle: Sender/receiver system; System part: Sender; Scanning range: 90 m; Dimension of the light pathMinimum10 m ... 70 mTypical10 m ... 90 m: Dimension of the light path; Number of beams: 3; Beam separation: 400 mm; Synchronization: Optical synchronisation; Items supplied: Sender; Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC...