DFS60 Inox

DFS60 Inox

Items 49 - 60 of 96 from SICK ⍾ Last modified Sep 3, 2025

DFS60 Inox ⍾ Page 5

Product detailsAdd to RFQ
DFS60I-S1MC65536 - Sick
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L ≡ 0...
Product detailsAdd to RFQ
DFS60I-Q4AC02500 - Sick
Performance: Pulses per revolution: 2,500 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Operating current: 40 mA...
Product detailsAdd to RFQ
DFS60I-Q4MK65536 - Sick
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L ≡ 0...
Product detailsAdd to RFQ
DFS60I-Q4PK65536 - Sick
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; Programmable/configurable: ✔; Initialization time: 32 ms 1)30 ms; Output frequency: ≤ 820...
Product detailsAdd to RFQ
DFS60I-BJEK01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5...
Product detailsAdd to RFQ
DFS60I-Q4AC08192 - Sick
Performance: Pulses per revolution: 8,192 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without...
Product detailsAdd to RFQ
DFS60I-BJWC01000 - Sick
Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L ≡ 0 - 3 V, H ≡...
Product detailsAdd to RFQ
DFS60I-Q4PC65536 - Sick
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; Programmable/configurable: ✔; Initialization time: 32 ms 1)30 ms; Output frequency: ≤ 820...
Product detailsAdd to RFQ
DFS60I-Q4CC01000 - Sick
Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5...
Product detailsAdd to RFQ
DFS60I-BHPC65536 - Sick
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; Programmable/configurable: ✔; Initialization time: 32 ms 1)30 ms; Output frequency: ≤ 820...
Product detailsAdd to RFQ
DFS60I-BHPK65536 - Sick
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; Programmable/configurable: ✔; Initialization time: 32 ms 1)30 ms; Output frequency: ≤ 820...
Product detailsAdd to RFQ
DFS60I-BHPM65536 - Sick
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; Programmable/configurable: ✔; Initialization time: 32 ms 1)30 ms; Output frequency: ≤ 820...