Items 1 - 12 of 17 from SICK ⍾ Last modified Sep 4, 2025

DFS60B-BC / DFS60 ⍾ Page 1

Product detailsAdd to RFQ
DFS60B-BCEA10000 - Sick
DFS60, Rotary.
Product detailsAdd to RFQ
DFS60B-BCAA00400 - Sick
DFS60, Rotary.
Product detailsAdd to RFQ
DFS60B-BCEC00200 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, Connector M12, 8-pin, radial.
Product detailsAdd to RFQ
DFS60B-BCEC01024 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, Connector M12, 8-pin, radial.
Product detailsAdd to RFQ
DFS60B-BCEM00016 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 5 m.
Product detailsAdd to RFQ
DFS60B-BCEL03160 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 3 m.
Product detailsAdd to RFQ
DFS60B-BCCA06000 - Sick
Performance: Pulses per revolution: 6,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60B-BCCK00105 - Sick
Performance: Pulses per revolution: 105 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60B-BCAK01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60B-BCAD10000 - Sick
Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product detailsAdd to RFQ
DFS60B-BCAA06000 - Sick
Performance: Pulses per revolution: 6,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product detailsAdd to RFQ
DFS60B-BCCL01000 - Sick
Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...