DFS60B-S4EK00010 - Sick
Performance: Pulses per revolution: 10 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-S4EK00100 - Sick
Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-S4EK00030 - Sick
Performance: Pulses per revolution: 30 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-S4EK00015 - Sick
Performance: Pulses per revolution: 15 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-S4EK00006 - Sick
Performance: Pulses per revolution: 6 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-S4EC04096 - Sick
Performance: Pulses per revolution: 4,096 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60B-S4ED03600 - Sick
Performance: Pulses per revolution: 3,600 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-S4ED03142 - Sick
Performance: Pulses per revolution: 3,142 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-S4EC08000 - Sick
Performance: Pulses per revolution: 8,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-S4EC08192 - Sick
Performance: Pulses per revolution: 8,192 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60B-S4EC04800 - Sick
Performance: Pulses per revolution: 4,800 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-S4ED00050 - Sick
Performance: Pulses per revolution: 50 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...