DFS60E-BCAC02048 - Sick
DFS60, Rotary. Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Connector M12, 8-pin, radial.
Product detailsAdd to RFQ
DFS60E-BCAK00200 - Sick
DFS60, Rotary. Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, 8-pin, universal, 1.5 m.
Product detailsAdd to RFQ
DFS60E-BCAK01024 - Sick
DFS60, Rotary. Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, 8-pin, universal, 1.5 m.
Product detailsAdd to RFQ
DFS60E-BCEK01024 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 1.5 m.
Product detailsAdd to RFQ
DFS60E-BCEC00360 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, Connector M12, 8-pin, radial.
Product detailsAdd to RFQ
DFS60E-BCAK02048 - Sick
DFS60, Rotary. Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, 8-pin, universal, 1.5 m.
Product detailsAdd to RFQ
DFS60E-BCEA01000 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, Connector M23, 12-pin, radial.
Product detailsAdd to RFQ
DFS60E-BCCK00100 - Sick
DFS60, Rotary.
Product detailsAdd to RFQ
DFS60E-BCEN01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60E-BCEA01250 - Sick
Performance: Pulses per revolution: 1,250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-BCAC01000 - Sick
Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product detailsAdd to RFQ
DFS60E-BCCA01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without load);...