[siemens_summary]
[catalog_children]
[catalog_search_products]
DFS60E-S1A / DFS60

DFS60E-S1A / DFS60

Items 1 - 7 of 7 from SICK ⍾ Last modified Sep 3, 2025

DFS60E-S1A / DFS60 ⍾ Page 1

Product detailsAdd to RFQ
DFS60E-S1AM02000 - Sick
Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product detailsAdd to RFQ
DFS60E-S1AK00512 - Sick
Performance: Pulses per revolution: 512 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60E-S1AK00200 - Sick
Performance: Pulses per revolution: 200 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product detailsAdd to RFQ
DFS60E-S1AD01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60E-S1AK00100 - Sick
Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product detailsAdd to RFQ
DFS60E-S1AA00512 - Sick
Performance: Pulses per revolution: 512 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60E-S1AB00500 - Sick
Performance: Pulses per revolution: 500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...