[siemens_summary]
[catalog_children]
[catalog_search_products]
DFS60E-S4E / DFS60

DFS60E-S4E / DFS60

Items 1 - 12 of 19 from SICK ⍾ Last modified Sep 3, 2025

DFS60E-S4E / DFS60 ⍾ Page 1

Product detailsAdd to RFQ
DFS60E-S4EN00500 - Sick
Performance: Pulses per revolution: 500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-S4EN01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60E-S4EN01000 - Sick
Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-S4EN02000 - Sick
Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-S4EM01000 - Sick
Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-S4EL01250 - Sick
Performance: Pulses per revolution: 1,250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-S4EL00512 - Sick
Performance: Pulses per revolution: 512 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60E-S4EL00200 - Sick
Performance: Pulses per revolution: 200 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-S4EL00100 - Sick
Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-S4ED00500 - Sick
Performance: Pulses per revolution: 500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-S4ED01000 - Sick
Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-S4EC01250 - Sick
Performance: Pulses per revolution: 1,250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...