[siemens_summary]
[catalog_children]
[catalog_search_products]

Distance Sensors ⍾ Page 26

Product detailsAdd to RFQ
DT50-P1114 - Sick
Dx50, DT50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 4,000 mm, 6 % remission, 200 mm ... 6,500 mm, 18 % remission. Response time: 20 ms / 30 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1 x PNP.
Product detailsAdd to RFQ
DT50-N2123 - Sick
Dx50, DT50 Hi. Measuring range: 200 mm ... 13,000 mm, 90 % remision, 200 mm ... 3,400 mm, 6 % remission, 200 mm ... 5,800 mm, 18 % remission. Response time: 15 ms / 30 ms / 80 ms. Repeatability: 3 mm / 2 mm / 1 mm. Light source: Laser, red. Laser protection class: 1 (EN 60825-1). Multifunctional input:...
Product detailsAdd to RFQ
DT50-P2113 - Sick
Dx50, DT50 Hi. Measuring range: 200 mm ... 20,000 mm, 90 % remision, 200 mm ... 5,000 mm, 6 % remission, 200 mm ... 8,500 mm, 18 % remission. Response time: 15 ms / 30 ms / 80 ms. Repeatability: 3 mm / 2 mm / 1 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input:...
Product detailsAdd to RFQ
DT50-N1114 - Sick
Dx50, DT50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 4,000 mm, 6 % remission, 200 mm ... 6,500 mm, 18 % remission. Response time: 20 ms / 30 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1 x NPN.
Product detailsAdd to RFQ
DT50-N1123 - Sick
Dx50, DT50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 2,500 mm, 6 % remission, 200 mm ... 5,000 mm, 18 % remission. Response time: 20 ms / 30 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 1 (EN 60825-1). Multifunctional input: 1 x NPN.
Product detailsAdd to RFQ
DT500-A623 - Sick
Dx500, DT500, CAN (Layer 2). Measuring range: 0.2 m ... 30 m, 6 % remission, 0.2 m ... 70 m, 90 % remision. Data interface: CAN (Layer 2). Ambient temperature: Operation with heating: -40 ... 50 °C, Operation with cooling case: -40 ... 75 °C, Storage: -25 ... 75 °C.
Product detailsAdd to RFQ
DT50-N2113 - Sick
Dx50, DT50 Hi. Measuring range: 200 mm ... 20,000 mm, 90 % remision, 200 mm ... 5,000 mm, 6 % remission, 200 mm ... 8,500 mm, 18 % remission. Response time: 15 ms / 30 ms / 80 ms. Repeatability: 3 mm / 2 mm / 1 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input:...
Product detailsAdd to RFQ
DT50-N1124 - Sick
Dx50, DT50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 2,500 mm, 6 % remission, 200 mm ... 5,000 mm, 18 % remission. Response time: 20 ms / 30 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 1 (EN 60825-1). Multifunctional input: 1 x NPN.
Product detailsAdd to RFQ
DT50-N1113 - Sick
Dx50, DT50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 4,000 mm, 6 % remission, 200 mm ... 6,500 mm, 18 % remission. Response time: 20 ms / 30 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1 x NPN.
Product detailsAdd to RFQ
DT500-A223 - Sick
Dx500, DT500, CAN (Layer 2). Measuring range: 0.2 m ... 18 m, 6 % remission, 0.2 m ... 30 m, 90 % remision. Data interface: CAN (Layer 2). Ambient temperature: Operation with heating: -40 ... 50 °C, Operation with cooling case: -40 ... 75 °C, Storage: -25 ... 75 °C.
Product detailsAdd to RFQ
DT500-A311 - Sick
Dx500, DT500, QA. Measuring range: 0.2 m ... 7 m, 6 % ... 90 % remission. Data interface: QA. Ambient temperature: Operation: -10 ... 50 °C, Operation with cooling case: -10 ... 75 °C, Storage: -25 ... 75 °C.
Product detailsAdd to RFQ
DT50-P1113 - Sick
Dx50, DT50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 4,000 mm, 6 % remission, 200 mm ... 6,500 mm, 18 % remission. Response time: 20 ms / 30 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1 x PNP.