DUV60E-D4KFWADA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFWCDB - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFWAAA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 2400 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFKBDB - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFWBDB - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFWCCB - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1800 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFWACA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1800 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFWABA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 2048 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFGAAA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 2400 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFJADA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFGDDB - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KFJAGA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 48 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...