[siemens_summary]
[catalog_children]
[catalog_search_products]

Encoders ⍾ Page 245

Product detailsAdd to RFQ
DUV60E-32KKAAAA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 2400 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: 1.4 million cycles 3); Ambient...
Product detailsAdd to RFQ
DUV60E-32KKBABA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 2048 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: 1.4 million cycles 3); Ambient...
Product detailsAdd to RFQ
DUV60E-D2KCKAAA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 2400 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-32KKHABA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 2048 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-D4KCHADA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-32KFBABA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 2048 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: 1.4 million cycles 3); Ambient...
Product detailsAdd to RFQ
DUV60E-32KFGCEA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 240 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-32KFBAAA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 2400 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: 1.4 million cycles 3); Ambient...
Product detailsAdd to RFQ
DUV60E-D2KCKCDA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-32KCWADA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-32KCKCAA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 2400 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...
Product detailsAdd to RFQ
DUV60E-32KFJACA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1800 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces:...