[siemens_summary]
[catalog_children]
[catalog_search_products]

Encoders ⍾ Page 247

Product detailsAdd to RFQ
DUV60E-00KFHAAA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 2400 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: 1.4 million cycles 2); Ambient...
Product detailsAdd to RFQ
DUV60E-00KFHCAB - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 2400 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: 1.4 million cycles 2); Ambient...
Product detailsAdd to RFQ
DUV60E-32KCAAGA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 48 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: 1.4 million cycles 3); Ambient...
Product detailsAdd to RFQ
DUV60E-32KCAACA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1800 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: 1.4 million cycles 3); Ambient...
Product detailsAdd to RFQ
DUV60E-32KCAAFA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 60 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: 1.4 million cycles 3); Ambient...
Product detailsAdd to RFQ
DUS60E-TKKFADCB - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...
Product detailsAdd to RFQ
DUV60E-00KCAACA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 1800 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: 1.4 million cycles 2); Ambient...
Product detailsAdd to RFQ
DUV60E-32KCAAEA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 240 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: 1.4 million cycles 3); Ambient...
Product detailsAdd to RFQ
DUS60E-TJKF0ACA - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...
Product detailsAdd to RFQ
DUS60E-TJKFAACA - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...
Product detailsAdd to RFQ
DUS60E-TJKF0AAA - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...
Product detailsAdd to RFQ
DUV60E-00KCAAAA - Sick
Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 ... 2400 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: 1.4 million cycles 2); Ambient...