Skip to content
About Us
Select Brand
ABB
Schneider
Phoneix Contact
Siemens
Innomotics
Weidmuller
Gewiss
Fluke
SICK
Baumer
Dungs
Krom schroder
Festo
Norgren
Foxboro
Telemecanique
IFM
Pilz
Contact Us
About Us
Select Brand
ABB
Schneider
Phoneix Contact
Siemens
Innomotics
Weidmuller
Gewiss
Fluke
SICK
Baumer
Dungs
Krom schroder
Festo
Norgren
Foxboro
Telemecanique
IFM
Pilz
Contact Us
RFQ
Catalog
>
SICK
>
Encoders
[siemens_summary]
[catalog_children]
[catalog_search_products]
Encoders
Items 4417 - 4428 of 10078
from
SICK
⍾ Last modified Sep 4, 2025
▲
Absolute encoders
Accessories
Incremental encoders
Linear encoders
Measuring wheel encoders
Safety encoders
Wire draw encoders
Search
Encoders ⍾ Page 369
«
1
…
367
368
369
370
371
…
840
»
Product details
Add to RFQ
DFS60B-TDPM10000 - Sick
DFS60, Rotary. Electrical interface: 4.5 V ... 32 V, TTL/HTL programmable, Cable, 8-pin, universal, 5 m.
Product details
Add to RFQ
DFS60B-TDEM00016 - Sick
Performance: Pulses per revolution: 16 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.05°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product details
Add to RFQ
DFS60B-TDNA01024 - Sick
Performance: Periods per revolution: 1,024; Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: Sin/Cos 1); Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 200 kHz; Operating current: 40 mA; Load resistance: ≤ 120 Ω; Electrical data: Connection type: Male...
Product details
Add to RFQ
DFS60B-TDNC01024 - Sick
Performance: Periods per revolution: 1,024; Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: Sin/Cos 1); Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 200 kHz; Operating current: 40 mA (without load); Load resistance: ≤ 120 Ω; Electrical data: Connection...
Product details
Add to RFQ
DFS60B-TDPC10000 - Sick
DFS60, Rotary. Electrical interface: 4.5 V ... 32 V, TTL/HTL programmable, Connector M12, 8-pin, radial.
Product details
Add to RFQ
DFS60B-TDEM05000 - Sick
Performance: Pulses per revolution: 5,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product details
Add to RFQ
DFS60B-TDEK00500 - Sick
Performance: Pulses per revolution: 500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product details
Add to RFQ
DFS60B-TDEK00250 - Sick
Performance: Pulses per revolution: 250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product details
Add to RFQ
DFS60B-TDEM02500 - Sick
Performance: Pulses per revolution: 2,500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product details
Add to RFQ
DFS60B-TDMA10000 - Sick
Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 -...
Product details
Add to RFQ
DFS60B-TDAC05000 - Sick
Performance: Pulses per revolution: 5,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product details
Add to RFQ
DFS60B-TDAA10000 - Sick
Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
« Prev page
Next page »