[siemens_summary]
[catalog_children]
[catalog_search_products]

Encoders ⍾ Page 560

Product detailsAdd to RFQ
DBV50E-22AKB0200 - Sick
Performance: Pulses per revolution: 200; Resolution in pulses/mm: 1; Measuring increment (resolution in mm/pulse): 1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22ANA0200 - Sick
Performance: Pulses per revolution: 200; Resolution in pulses/mm: 1; Measuring increment (resolution in mm/pulse): 1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22AMA1000 - Sick
Performance: Pulses per revolution: 1,000; Resolution in pulses/mm: 5; Measuring increment (resolution in mm/pulse): 0.2, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22AMA2500 - Sick
Performance: Pulses per revolution: 2,500; Resolution in pulses/mm: 12.5; Measuring increment (resolution in mm/pulse): 0.08, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22ALA2500 - Sick
Performance: Pulses per revolution: 2,500; Resolution in pulses/mm: 12.5; Measuring increment (resolution in mm/pulse): 0.08, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBS60I-S4FM05000 - Sick
Performance: Pulses per revolution: 5,000; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Number of signal channels: 6-channel; Initialization time: < 5 ms 2); Output frequency: ≤ 300...
Product detailsAdd to RFQ
DBV50E-00GPB2000 - Sick
Performance: Pulses per revolution: 2,000; Resolution in pulses/mm: 10; Measuring increment (resolution in mm/pulse): 0.1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 0.4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 3); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22AJA1000 - Sick
Performance: Pulses per revolution: 1,000; Resolution in pulses/mm: 5; Measuring increment (resolution in mm/pulse): 0.2, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBV50E-22AMA2000 - Sick
Performance: Pulses per revolution: 2,000; Resolution in pulses/mm: 10; Measuring increment (resolution in mm/pulse): 0.1, ± 18° / pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 4 mm/m, subject to the measuring wheel (wheel + surface); Duty cycle: ≤ 0.5 ± 5 %; Initialization time: 1.4 million cycles 4); Mounting position relative to...
Product detailsAdd to RFQ
DBS60I-S4EM01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: ≤ 300...
Product detailsAdd to RFQ
DBS60I-S4FM02000 - Sick
Performance: Pulses per revolution: 2,000; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Number of signal channels: 6-channel; Initialization time: < 5 ms 2); Output frequency: ≤ 300...
Product detailsAdd to RFQ
DBS60I-Q4FM01000 - Sick
Performance: Pulses per revolution: 1,000; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Number of signal channels: 6-channel; Initialization time: < 5 ms 2); Output frequency: ≤ 300...