SBN433 - Ifm
Flow transmitter with integrated backflow prevention; Operating voltage [V] : 18...32 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Output signal : analogue signal; Analogue current output [mA] : 4...20; Max. load [Ω] : 500; Short-circuit protection : yes; Overload protection : yes; Measuring range [gpm] : 0.2...6; Repeatability [% of the final value] : 1;...
Product detailsAdd to RFQ
SBU924 - Ifm
Flow transmitter with integrated backflow prevention; Operating voltage tolerance [%] : -15...10; Operating voltage [V] : 24 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Output signal : analogue signal; Analogue voltage output [V] : 0.5...10; Min. load resistance [Ω] : 10000; Short-circuit protection : yes; Overload protection : yes; Measuring range [l/min] : 2...50; Flow...
Product detailsAdd to RFQ
SBY232 - Ifm
Flow meter with integrated backflow prevention and display; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1 l/min); Response time [s] : 0.01; Damping for the switching output dAP [s] : 0...5; Damping for the analogue output dAA [s] : 0...5; Parameter setting options...
Product detailsAdd to RFQ
SBY321 - Ifm
Flow sensor with integrated backflow prevention; Operating voltage [V] : 10...30 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Total number of outputs : 1; Output signal : switching signal; Electrical design : PNP; Number of digital outputs : 1; Output function : normally open; Max. voltage drop switching output DC [V] : 2.5; Permanent current...
Product detailsAdd to RFQ
SBY246 - Ifm
Flow meter with integrated backflow prevention and display; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1 l/min); Response time [s] : 0.01; Damping for the switching output dAP [s] : 0...5; Damping for the analogue output dAA [s] : 0...5; Parameter setting options...
Product detailsAdd to RFQ
SBY233 - Ifm
Flow meter with integrated backflow prevention and display; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1 l/min); Response time [s] : 0.01; Damping for the switching output dAP [s] : 0...5; Damping for the analogue output dAA [s] : 0...5; Parameter setting options...
Product detailsAdd to RFQ
SBY334 - Ifm
Flow sensor with integrated backflow prevention; Operating voltage [V] : 10...30 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Total number of outputs : 1; Output signal : switching signal; Electrical design : PNP; Number of digital outputs : 1; Output function : normally open; Max. voltage drop switching output DC [V] : 2.5; Permanent current...
Product detailsAdd to RFQ
SBY323 - Ifm
Flow sensor with integrated backflow prevention; Operating voltage [V] : 10...30 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Total number of outputs : 1; Output signal : switching signal; Electrical design : PNP; Number of digital outputs : 1; Output function : normally open; Max. voltage drop switching output DC [V] : 2.5; Permanent current...
Product detailsAdd to RFQ
SBY234 - Ifm
Flow meter with integrated backflow prevention and display; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1 l/min); Response time [s] : 0.01; Damping for the switching output dAP [s] : 0...5; Damping for the analogue output dAA [s] : 0...5; Parameter setting options...
Product detailsAdd to RFQ
SBY257 - Ifm
Flow meter with integrated backflow prevention and display; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1 l/min); Response time [s] : 0.01; Damping for the switching output dAP [s] : 0...5; Damping for the analogue output dAA [s] : 0...5; Parameter setting options...
Product detailsAdd to RFQ
SBT633 - Ifm
Flow transmitter with integrated backflow prevention; Operating voltage tolerance [%] : -15...10; Operating voltage [V] : 24 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Output signal : analogue signal; Analogue current output [mA] : 4...20; Max. load [Ω] : 500; Short-circuit protection : yes; Overload protection : yes; Measuring range [l/min] : 0.3...25; Repeatability [%...
Product detailsAdd to RFQ
SBY332 - Ifm
Flow sensor with integrated backflow prevention; Operating voltage [V] : 10...30 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Total number of outputs : 1; Output signal : switching signal; Electrical design : PNP; Number of digital outputs : 1; Output function : normally open; Max. voltage drop switching output DC [V] : 2.5; Permanent current...