[siemens_summary]
[catalog_children]
[catalog_search_products]

Flow sensors / flow meters ⍾ Page 2

Product detailsAdd to RFQ
SV5150 - Ifm
Vortex flow meter; Operating voltage [V] : 8...33 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Power-on delay time [s] : < 2; Total number of outputs : 1; Output signal : analogue signal; Number of analogue outputs : 1; Analogue current output [mA] : 4...20; (water: Q [l/min] = 2,0 x (I -...
Product detailsAdd to RFQ
SV5504 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : analogue signal; Number of analogue outputs : 2; Analogue current output [mA] : 4...20; Max....
Product detailsAdd to RFQ
SV5614 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : analogue signal; Number of analogue outputs : 2; Analogue current output [mA] : 4...20; Max....
Product detailsAdd to RFQ
SV5204 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : analogue signal; Number of analogue outputs : 2; Analogue current output [mA] : 4...20; Max....
Product detailsAdd to RFQ
SV5500 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : switching signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs :...
Product detailsAdd to RFQ
SV6050 - Ifm
Vortex flow meter; Operating voltage [V] : 8...33 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Power-on delay time [s] : < 2; Total number of outputs : 1; Output signal : analogue signal; Number of analogue outputs : 1; Analogue current output [mA] : 4...20; (water: Q [l/min] = 3,125 x (I -...
Product detailsAdd to RFQ
SV5200 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : switching signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs :...
Product detailsAdd to RFQ
SV5610 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : switching signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs :...
Product detailsAdd to RFQ
SV7200 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : switching signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs :...
Product detailsAdd to RFQ
SV7204 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : analogue signal; Number of analogue outputs : 2; Analogue current output [mA] : 4...20; Max....
Product detailsAdd to RFQ
SV7050 - Ifm
Vortex flow meter; Operating voltage [V] : 8...33 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Power-on delay time [s] : < 2; Total number of outputs : 1; Output signal : analogue signal; Number of analogue outputs : 1; Analogue current output [mA] : 4...20; (water: Q [l/min] = 5,313 x (I -...
Product detailsAdd to RFQ
SV4050 - Ifm
Vortex flow meter; Operating voltage [V] : 8...33 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Power-on delay time [s] : < 2; Total number of outputs : 1; Output signal : analogue signal; Number of analogue outputs : 1; Analogue current output [mA] : 4...20; (Q [l/min] = 0,938 x (I - 4...