[siemens_summary]
[catalog_children]
[catalog_search_products]

Flow sensors / flow meters ⍾ Page 3

Product detailsAdd to RFQ
SU8200 - Ifm
Ultrasonic flow meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Total number of outputs : 2; Output signal : switching signal; Electrical design : PNP; Number of digital outputs : 2; Output function...
Product detailsAdd to RFQ
SV4500 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : switching signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs :...
Product detailsAdd to RFQ
SU9000 - Ifm
Ultrasonic flow meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design :...
Product detailsAdd to RFQ
SU7200 - Ifm
Ultrasonic flow meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Total number of outputs : 2; Output signal : switching signal; Electrical design : PNP; Number of digital outputs : 2; Output function...
Product detailsAdd to RFQ
SU8001 - Ifm
Ultrasonic flow meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design :...
Product detailsAdd to RFQ
SU8000 - Ifm
Ultrasonic flow meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design :...
Product detailsAdd to RFQ
SU9004 - Ifm
Ultrasonic flow meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Total number of outputs : 2; Output signal : analogue signal; Number of analogue outputs : 2; Analogue current output [mA] : 4...20;...
Product detailsAdd to RFQ
SU7001 - Ifm
Ultrasonic flow meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design :...
Product detailsAdd to RFQ
SU9001 - Ifm
Ultrasonic flow meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design :...
Product detailsAdd to RFQ
SU7000 - Ifm
Ultrasonic flow meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design :...
Product detailsAdd to RFQ
SV4150 - Ifm
Vortex flow meter; Operating voltage [V] : 8...33 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Power-on delay time [s] : < 2; Total number of outputs : 1; Output signal : analogue signal; Number of analogue outputs : 1; Analogue current output [mA] : 4...20; (Q [l/min] = 0,938 x (I - 4...
Product detailsAdd to RFQ
SV4204 - Ifm
Vortex flow meter with display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 3; Total number of outputs : 2; Output signal : analogue signal; Number of analogue outputs : 2; Analogue current output [mA] : 4...20; Max....