Flow sensors

Flow sensors

Items 25 - 36 of 39 from SICK ⍾ Last modified Sep 3, 2025

Flow sensors ⍾ Page 3

Product detailsAdd to RFQ
FFUC20-1N1IO - Sick
Features: Measurement principle: Ultrasonic sensor; Medium: Fluids; Nominal width measuring tube: DN 20; Process temperature: 0 °C ... +80 °C; Process pressure: Max. 10 bar; Performance: Minimim flow: ≥ 3.5 l/min 1); Maximum flow: 0 l/min ... 60 l/min; Inlet zone: 40 cm; Output zone: 10 cm; Conductivity: No limitation; Accuracy of sensor element: 1 % of reading ± 3...
Product detailsAdd to RFQ
FFUC25-1N1IO - Sick
Features: Measurement principle: Ultrasonic sensor; Medium: Fluids; Nominal width measuring tube: DN 25; Process temperature: 0 °C ... +80 °C; Process pressure: Max. 10 bar; Performance: Minimim flow: ≥ 5 l/min 1); Maximum flow: 0 l/min ... 240 l/min; Inlet zone: 40 cm; Output zone: 20 cm; Conductivity: No limitation; Accuracy of sensor element: 1 % of reading ± 3...
Product detailsAdd to RFQ
FFUC25-1N1SR - Sick
Features: Measurement principle: Ultrasonic sensor; Medium: Fluids; Nominal width measuring tube: DN 25; Process temperature: 0 °C ... +80 °C; Process pressure: Max. 10 bar; Performance: Minimim flow: ≥ 5 l/min 1); Maximum flow: 0 l/min ... 240 l/min; Inlet zone: 40 cm; Output zone: 20 cm; Conductivity: No limitation; Accuracy of sensor element: 1 % of reading ± 3...
Product detailsAdd to RFQ
FFUC25-1G1SR - Sick
Features: Measurement principle: Ultrasonic sensor; Medium: Fluids; Nominal width measuring tube: DN 25; Process temperature: 0 °C ... +80 °C; Process pressure: Max. 10 bar; Performance: Minimim flow: ≥ 5 l/min 1); Maximum flow: 0 l/min ... 240 l/min; Inlet zone: 40 cm; Output zone: 20 cm; Conductivity: No limitation; Accuracy of sensor element: 1 % of reading ± 3...
Product detailsAdd to RFQ
FFUC10-1G1SR - Sick
Features: Measurement principle: Ultrasonic sensor; Medium: Fluids; Nominal width measuring tube: DN 10; Process temperature: 0 °C ... +80 °C; Process pressure: Max. 16 bar; Performance: Minimim flow: ≥ 0.3 l/min 1); Maximum flow: 0 l/min ... 21 l/min; Inlet zone: 10 cm; Output zone: 0 cm; Conductivity: No limitation; Accuracy of sensor element: 1 % of reading ± 3...
Product detailsAdd to RFQ
FFUC10-1N1IO - Sick
Features: Measurement principle: Ultrasonic sensor; Medium: Fluids; Nominal width measuring tube: DN 10; Process temperature: 0 °C ... +80 °C; Process pressure: Max. 16 bar; Performance: Minimim flow: ≥ 0.3 l/min 1); Maximum flow: 0 l/min ... 21 l/min; Inlet zone: 10 cm; Output zone: 0 cm; Conductivity: No limitation; Accuracy of sensor element: 1 % of reading ± 3...
Product detailsAdd to RFQ
FFUC15-1C1SR - Sick
Features: Measurement principle: Ultrasonic sensor; Medium: Fluids; Nominal width measuring tube: DN 15; Process temperature: 0 °C ... +80 °C; Process pressure: Max. 16 bar; Performance: Minimim flow: ≥ 0.9 l/min 1); Maximum flow: 0 l/min ... 36 l/min; Inlet zone: 30 cm; Output zone: 5 cm; Conductivity: No limitation; Accuracy of sensor element: 1 % of reading ± 3...
Product detailsAdd to RFQ
FFUS10-1C1IO - Sick
Ultrasonic flowmeter. Process temperature: 0 °C ... 80 °C. Maximum flow: 21 l/min. Process connection: Clamp (DIN 11864-3) DN 10 form A.
Product detailsAdd to RFQ
FFUC15-1G1IO - Sick
Features: Measurement principle: Ultrasonic sensor; Medium: Fluids; Nominal width measuring tube: DN 15; Process temperature: 0 °C ... +80 °C; Process pressure: Max. 16 bar; Performance: Minimim flow: ≥ 0.9 l/min 1); Maximum flow: 0 l/min ... 36 l/min; Inlet zone: 30 cm; Output zone: 5 cm; Conductivity: No limitation; Accuracy of sensor element: 1 % of reading ± 3...
Product detailsAdd to RFQ
FFUC20-1C1SR - Sick
Features: Measurement principle: Ultrasonic sensor; Medium: Fluids; Nominal width measuring tube: DN 20; Process temperature: 0 °C ... +80 °C; Process pressure: Max. 10 bar; Performance: Minimim flow: ≥ 3.5 l/min 1); Maximum flow: 0 l/min ... 60 l/min; Inlet zone: 40 cm; Output zone: 10 cm; Conductivity: No limitation; Accuracy of sensor element: 1 % of reading ± 3...
Product detailsAdd to RFQ
FFUC10-1G1IO - Sick
Features: Measurement principle: Ultrasonic sensor; Medium: Fluids; Nominal width measuring tube: DN 10; Process temperature: 0 °C ... +80 °C; Process pressure: Max. 16 bar; Performance: Minimim flow: ≥ 0.3 l/min 1); Maximum flow: 0 l/min ... 21 l/min; Inlet zone: 10 cm; Output zone: 0 cm; Conductivity: No limitation; Accuracy of sensor element: 1 % of reading ± 3...
Product detailsAdd to RFQ
FFUC10-1C1SR - Sick
Features: Measurement principle: Ultrasonic sensor; Medium: Fluids; Nominal width measuring tube: DN 10; Process temperature: 0 °C ... +80 °C; Process pressure: Max. 16 bar; Performance: Minimim flow: ≥ 0.3 l/min 1); Maximum flow: 0 l/min ... 21 l/min; Inlet zone: 10 cm; Output zone: 0 cm; Conductivity: No limitation; Accuracy of sensor element: 1 % of reading ± 3...