Product detailsAdd to RFQ
THTS-1PBVB0506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Varivent connector type B, DN 10, DN 15; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 25 bar at room...
Product detailsAdd to RFQ
THTS-1PBT50756MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Tri-clamp ½", ¾"; Insertion length/diameter of probe: 75 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16 bar at room temperature; Housing material: Stainless steel...
Product detailsAdd to RFQ
THTS-1PBT20506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Tri-Clamp 2"; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16 bar at room temperature; Housing material: Stainless steel (CrNi);...
Product detailsAdd to RFQ
THTS-1PBC30506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Clamp (ISO 2852) DN 25, DN 33.7, DN 38; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16 bar at...
Product detailsAdd to RFQ
THTS-1PBT50506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Tri-clamp ½", ¾"; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16 bar at room temperature; Housing material: Stainless steel...
Product detailsAdd to RFQ
THTS-1PBVF0506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Varivent connection type F, DN 25; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 25 bar at room temperature; Housing...
Product detailsAdd to RFQ
THTS-1PBT51506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Tri-clamp ½", ¾"; Insertion length/diameter of probe: 150 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16 bar at room temperature; Housing material: Stainless steel...
Product detailsAdd to RFQ
THTS-1PBD40506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Clamp (DIN 32676) DN 25, DN 32, DN 40; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16 bar at...
Product detailsAdd to RFQ
THTS-1PBD20506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Clamp (DIN 32676) DN 10, DN 15, DN 20; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16 bar at...
Product detailsAdd to RFQ
THTS-1PBC50506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Clamp (ISO 2852) DN 40, DN 51; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16 bar at room temperature;...
Product detailsAdd to RFQ
THTS-1PBC31506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Clamp (ISO 2852) DN 25, DN 33.7, DN 38; Insertion length/diameter of probe: 150 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16 bar at...
Product detailsAdd to RFQ
THTS-1PBC20506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Clamp (ISO 2852) DN 12, DN 12.7, DN 17.2, DN 21.3; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16...