THTS-1PB550506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Conical coupling (DIN 11851) DN 50 with union nut; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 25 bar at...
Product detailsAdd to RFQ
THTS-1PB510506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Conical coupling (DIN 11851) DN 20 with union nut; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 40 bar at...
Product detailsAdd to RFQ
THTS-1PAVN0506MZ - Sick
Features: Measuring range: –50 °C +150 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Varivent connection type N, DN 40; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16 bar at room temperature; Housing...
Product detailsAdd to RFQ
THTS-1PAVB0506MZ - Sick
Features: Measuring range: –50 °C +150 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Varivent connector type B, DN 10, DN 15; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 25 bar at room...
Product detailsAdd to RFQ
THTS-1PB520506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Conical coupling (DIN 11851) DN 25 with union nut; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 40 bar at...
Product detailsAdd to RFQ
THTS-1PB540506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Conical coupling (DIN 11851) DN 40 with union nut; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 40 bar at...
Product detailsAdd to RFQ
THTS-1PB530506MZ - Sick
Features: Measuring range: –50 °C +250 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Conical coupling (DIN 11851) DN 32 with union nut; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 40 bar at...
Product detailsAdd to RFQ
THTS-1PAT20506MZ - Sick
Features: Measuring range: –50 °C +150 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Tri-Clamp 2"; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16 bar at room temperature; Housing material: Stainless steel (CrNi);...
Product detailsAdd to RFQ
THTS-1PAD50506MZ - Sick
Features: Measuring range: –50 °C +150 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Clamp (DIN 32676) DN 50; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16 bar at room temperature; Housing material:...
Product detailsAdd to RFQ
THTS-1PAVF0506MZ - Sick
Features: Measuring range: –50 °C +150 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Varivent connection type F, DN 25; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 25 bar at room temperature; Housing...
Product detailsAdd to RFQ
THTS-1PAD40506MZ - Sick
Features: Measuring range: –50 °C +150 °C; Sensor element: Pt100, Pt1000 (for 4 mA ... 20 mA version); Output signal: Pt100, 4-wire; Mechanics/electronics: Process connection: Clamp (DIN 32676) DN 25, DN 32, DN 40; Insertion length/diameter of probe: 50 mm / 6 mm; Wetted parts: Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm; Pressure resistance: Max. 16 bar at...
Product detailsAdd to RFQ
THTS-1PAT10506MZ - Sick
Resistance thermometer. Process connection: Tri-clamp 1', 1 ½'. Insertion length/diameter of probe: 50 mm / 6 mm. Electrical connection/enclosure rating: Round connector M12 x 1, 4-pin / IP 68 and IP 69K.