[siemens_summary]
[catalog_children]
[catalog_search_products]

IFM ⍾ Page 1

Product detailsAdd to RFQ
SR5906 - Ifm
Control monitor for flow sensors; Frequency AC [Hz] : 47...63; Operating voltage tolerance [%] : -15...10; Operating voltage [V] : 90...240 AC; Max. power consumption [VA] : 3.5; Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 10; Number of channels : 1; Electrical design : relay; Contact rating : 3 A (250 V AC...
Product detailsAdd to RFQ
SI5006 - Ifm
Flow monitor; Response time [s] : 1...10; Frequency AC [Hz] : 47...63; Operating voltage tolerance [%] : -15...10; Operating voltage [V] : 90...240 AC; Max. power consumption [VA] : 3.5; Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 10; Total number of outputs : 1; Output signal : switching signal; Electrical design : relay;...
Product detailsAdd to RFQ
PY9920 - Ifm
Pressure sensor with display; Operating voltage tolerance [%] : 5...10; Operating voltage [V] : 85...265 AC; Nominal voltage AC [V] : < 250; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 0.2; Integrated watchdog : yes; Total number of outputs : 1; Output signal :...
Product detailsAdd to RFQ
PN4223 - Ifm
Pressure sensor with display; Operating voltage tolerance [%] : 5...10; Operating voltage [V] : 85...265 AC; Nominal voltage AC [V] : < 250; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 0.2; Integrated watchdog : yes; Total number of outputs : 1; Output signal :...
Product detailsAdd to RFQ
PN4221 - Ifm
Pressure sensor with display; Operating voltage tolerance [%] : < 10; Operating voltage [V] : 85...265 AC; Nominal voltage AC [V] : < 250; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 0.2; Integrated watchdog : yes; Total number of outputs : 1; Output signal...
Product detailsAdd to RFQ
PN4222 - Ifm
Pressure sensor with display; Operating voltage tolerance [%] : 5...10; Operating voltage [V] : 85...265 AC; Nominal voltage AC [V] : < 250; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 0.2; Integrated watchdog : yes; Total number of outputs : 1; Output signal :...
Product detailsAdd to RFQ
PN4229 - Ifm
Pressure sensor with display; Operating voltage tolerance [%] : 5...10; Operating voltage [V] : 85...265 AC; Nominal voltage AC [V] : < 250; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 0.2; Integrated watchdog : yes; Total number of outputs : 1; Output signal :...
Product detailsAdd to RFQ
PN4224 - Ifm
Pressure sensor with display; Operating voltage tolerance [%] : 5...10; Operating voltage [V] : 85...265 AC; Nominal voltage AC [V] : < 250; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 0.2; Integrated watchdog : yes; Total number of outputs : 1; Output signal :...
Product detailsAdd to RFQ
PN4227 - Ifm
Pressure sensor with display; Operating voltage tolerance [%] : 5...10; Operating voltage [V] : 85...265 AC; Nominal voltage AC [V] : < 250; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 0.2; Integrated watchdog : yes; Total number of outputs : 1; Output signal :...
Product detailsAdd to RFQ
PN4226 - Ifm
Pressure sensor with display; Operating voltage tolerance [%] : 5...10; Operating voltage [V] : 85...265 AC; Nominal voltage AC [V] : < 250; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 0.2; Integrated watchdog : yes; Total number of outputs : 1; Output signal :...
Product detailsAdd to RFQ
PN4220 - Ifm
Pressure sensor with display; Operating voltage tolerance [%] : 5...10; Operating voltage [V] : 85...265 AC; Nominal voltage AC [V] : < 250; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 0.2; Integrated watchdog : yes; Total number of outputs : 1; Output signal :...
Product detailsAdd to RFQ
OL0010 - Ifm
Retro-reflective sensor; Frequency AC [Hz] : 47...63; Operating voltage [V] : 20...250 AC/DC; Max. power consumption [VA] : 4; Protection class : I; Reverse polarity protection : no; Type of light : red light; Wave length [nm] : 660; Typ. lifetime [h] : 100000; Reference temperature for service life [°C] : 25; Electrical design : relay; Output function : light-on/dark-on...