[siemens_summary]
[catalog_children]
[catalog_search_products]

Incremental encoders ⍾ Page 115

Product detailsAdd to RFQ
Kopie von DFS60B-BHAK04096 - Sick
Performance: Pulses per revolution: 4,096 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DUS60E-TKKFADCB - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...
Product detailsAdd to RFQ
DUS60E-TJKF0ACA - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...
Product detailsAdd to RFQ
DUS60E-TJKFAACA - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...
Product detailsAdd to RFQ
DUS60E-TJKF0AAA - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...
Product detailsAdd to RFQ
DUS60E-TJKM0ACA - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...
Product detailsAdd to RFQ
DUS60E-TKKCAACA - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...
Product detailsAdd to RFQ
DUS60E-TJKC0ACA - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...
Product detailsAdd to RFQ
DUS60E-TJKC0ABA - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...
Product detailsAdd to RFQ
DUS60E-TEKKAACA - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...
Product detailsAdd to RFQ
DUS60E-TJKC0AAA - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...
Product detailsAdd to RFQ
DUS60E-THKKAAAA - Sick
Performance: Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Parameterising data: DIP switch, selectable output; Output function: A and B output; Initialization time: < 5 ms 2); Output...