[siemens_summary]
[catalog_children]
[catalog_search_products]

Incremental encoders ⍾ Page 142

Product detailsAdd to RFQ
DGS35-3LL01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 45° / pulses per revolution; Error limits: ± 45° / pulses per revolution; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Output frequency: 300 kHz; Load current: 40 mA; Operating current: 100 mA (without load); Electrical data: Connection type: Cable, 11-wire, radial, 3...
Product detailsAdd to RFQ
DGS35-3L402048 - Sick
Performance: Pulses per revolution: 2,048; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 45° / pulses per revolution; Error limits: ± 45° / pulses per revolution; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Output frequency: 300 kHz; Load current: 40 mA; Operating current: 100 mA (without load); Electrical data: Connection type: Male connector, MS, 10-pin,...
Product detailsAdd to RFQ
DGS35-5H401024 - Sick
Encoder, Rotary.
Product detailsAdd to RFQ
DGS35-3KK02048 - Sick
Performance: Pulses per revolution: 2,048; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 45° / pulses per revolution; Error limits: ± 45° / pulses per revolution; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Output frequency: 300 kHz; Load current: 40 mA; Operating current: 100 mA (without load); Electrical data: Connection type: Cable, 11-wire, radial, 1.5...
Product detailsAdd to RFQ
DGS35-5H400360 - Sick
Encoder, Rotary.
Product detailsAdd to RFQ
DGS35-3KK01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 45° / pulses per revolution; Error limits: ± 45° / pulses per revolution; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Output frequency: 300 kHz; Load current: 40 mA; Operating current: 100 mA (without load); Electrical data: Connection type: Cable, 11-wire, radial, 1.5...
Product detailsAdd to RFQ
DGS35-3K402048 - Sick
Performance: Pulses per revolution: 2,048; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 45° / pulses per revolution; Error limits: ± 45° / pulses per revolution; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Output frequency: 300 kHz; Load current: 40 mA; Operating current: 100 mA (without load); Electrical data: Connection type: Male connector, MS, 10-pin,...
Product detailsAdd to RFQ
DGS35-5H402048 - Sick
Encoder, Rotary.
Product detailsAdd to RFQ
DGS35-3J401024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 45° / pulses per revolution; Error limits: ± 45° / pulses per revolution; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Output frequency: 300 kHz; Load current: 40 mA; Operating current: 100 mA (without load); Electrical data: Connection type: Male connector, MS, 10-pin,...
Product detailsAdd to RFQ
DGS35-3K401024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 45° / pulses per revolution; Error limits: ± 45° / pulses per revolution; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Output frequency: 300 kHz; Load current: 40 mA; Operating current: 100 mA (without load); Electrical data: Connection type: Male connector, MS, 10-pin,...
Product detailsAdd to RFQ
DGS35-1KK02500 - Sick
Performance: Pulses per revolution: 2,500; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 45° / pulses per revolution; Error limits: ± 45° / pulses per revolution; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Output frequency: 300 kHz; Load current: 40 mA; Operating current: 120 mA (without load); Electrical data: Connection type: Cable, 11-wire, radial, 1.5...
Product detailsAdd to RFQ
DGS35-2K405000 - Sick
Performance: Pulses per revolution: 5,000; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 45° / pulses per revolution; Error limits: ± 45° / pulses per revolution; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Output frequency: 300 kHz; Load current: 40 mA; Operating current: 100 mA (without load); Electrical data: Connection type: Male connector, MS, 10-pin,...