[siemens_summary]
[catalog_children]
[catalog_search_products]

Incremental encoders ⍾ Page 161

Product detailsAdd to RFQ
DFS60E-TECA00100 - Sick
Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60E-TEEL02048 - Sick
Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60E-TEEC00S03 - Sick
Features: Special device: ✔; Specialty: Statour coupling (4062430) premounted; Standard reference device: DFS60E-TEEC00360, 1065098; Performance: Pulses per revolution: 360 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output...
Product detailsAdd to RFQ
DFS60E-TECL00250 - Sick
Performance: Pulses per revolution: 250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60E-TECK02048 - Sick
Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without load);...
Product detailsAdd to RFQ
DFS60E-TEEM00512 - Sick
Performance: Pulses per revolution: 512 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60E-TECL01250 - Sick
Performance: Pulses per revolution: 1,250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60E-TEEL00250 - Sick
Performance: Pulses per revolution: 250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-TEEM00100 - Sick
Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-TEAA02000 - Sick
Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product detailsAdd to RFQ
DFS60E-TEAK02048 - Sick
Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60E-TEEL00S02 - Sick
Features: Special device: ✔; Specialty: Stator coupling 2059368 premounted; Standard reference device: DFS60E-TEEL00360, 1054197; Performance: Pulses per revolution: 360 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output...