DFS60E-TDEC00314 - Sick
Performance: Pulses per revolution: 314 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-TDEC02000 - Sick
Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-TDEK00100 - Sick
Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-TDEL00500 - Sick
Performance: Pulses per revolution: 500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-TEAM02048 - Sick
Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60E-TDEL01000 - Sick
Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-TDEC00500 - Sick
Performance: Pulses per revolution: 500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-TDEN00500 - Sick
Performance: Pulses per revolution: 500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60E-TDEN01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60E-TDAC02048 - Sick
Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60E-TDAC01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60E-TDEM02048 - Sick
Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...