[siemens_summary]
[catalog_children]
[catalog_search_products]

Incremental encoders ⍾ Page 200

Product detailsAdd to RFQ
DFS60E-BAEA00500 - Sick
Performance: Pulses per revolution: 500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-TJPZ00S06 - Sick
Features: Special device: ✔; Specialty: Cable, universal, 0.5 m with M12 5-pin, customized label; Standard reference device: DFS60B-TJPK10000, 1036928; Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level...
Product detailsAdd to RFQ
DFS60B-TJPZ00S07 - Sick
Features: Special device: ✔; Specialty: DFS60B-TJPZ00S06 (1100135) cable, universal, 0.5 m with M12 8-pin, additional accessories included with deliveryCustomized label:6028369 M12-8 pin female connector2076219 8 mm collet2076220 10 mm collet2076221 12 mm collet2076222 14 mm collet2076223 15 mm colletAdditional empty label to note the programming settings; Standard reference device: DFS60B-TJPK65536, 1036968; Performance: Pulses per revolution: 10,000 1); Measuring step: 90°...
Product detailsAdd to RFQ
DFS60E-BAAL01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60E-BAEA02048 - Sick
Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60E-BAAK02000 - Sick
Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product detailsAdd to RFQ
DFS60E-BACN01000 - Sick
Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 300 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60B-TJPM10000 - Sick
DFS60, Rotary. Electrical interface: 4.5 V ... 32 V, TTL/HTL programmable, Cable, 8-pin, universal, 5 m.
Product detailsAdd to RFQ
DFS60B-TJWA03600 - Sick
Performance: Pulses per revolution: 3,600 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 -...
Product detailsAdd to RFQ
DFS60B-TJPC10000 - Sick
DFS60, Rotary. Electrical interface: 4.5 V ... 32 V, TTL/HTL programmable, Connector M12, 8-pin, radial.
Product detailsAdd to RFQ
DFS60B-TJPA10000 - Sick
DFS60, Rotary. Electrical interface: Connector M23, 12-pin, radial, TTL/HTL programmable.
Product detailsAdd to RFQ
DFS60B-TJPL10000 - Sick
DFS60, Rotary. Electrical interface: 4.5 V ... 32 V, TTL/HTL programmable, Cable, 8-pin, universal, 3 m.