DFS60B-S4UA08192 - Sick
DFS60, Rotary. Electrical interface: Connector M23, 12-pin, radial, TTL/RS422, 0-SET.
Product detailsAdd to RFQ
DFS60B-S4UA03000 - Sick
Performance: Pulses per revolution: 3,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us...
Product detailsAdd to RFQ
DFS60B-S4UA03600 - Sick
Performance: Pulses per revolution: 3,600 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us...
Product detailsAdd to RFQ
DFS60B-S4UB00080 - Sick
Performance: Pulses per revolution: 80 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us...
Product detailsAdd to RFQ
DFS60B-S4UB00360 - Sick
Performance: Pulses per revolution: 360 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us...
Product detailsAdd to RFQ
DFS60B-S4UA02048 - Sick
Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us V...
Product detailsAdd to RFQ
DFS60B-S4UA06000 - Sick
Performance: Pulses per revolution: 6,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us...
Product detailsAdd to RFQ
DFS60B-S4UA04096 - Sick
DFS60, Rotary. Electrical interface: Connector M23, 12-pin, radial, TTL/RS422, 0-SET.
Product detailsAdd to RFQ
DFS60B-S4UA02500 - Sick
DFS60, Rotary. Electrical interface: Connector M23, 12-pin, radial, TTL/RS422, 0-SET.
Product detailsAdd to RFQ
DFS60B-S4UA02000 - Sick
Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us...
Product detailsAdd to RFQ
DFS60B-S4PZ00S93 - Sick
Features: Special device: ✔; Specialty: Connector M23, 12-pin, axial with customer specific pin allocationPulses per revolution: preprogrammed to 2500Electrical interface: preprogrammed to HTL; Standard reference device: DFS60B-S4PB10000, 1056523; Performance: Pulses per revolution: 2,500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail:...
Product detailsAdd to RFQ
DFS60B-S4PZ00S69 - Sick
Features: Special device: ✔; Specialty: Customized pin assignment4.5 ... 32 V, TTL/HTL programmable, preset HTLResolution programmable, preset 7,500 pulsesBEF-MR10300AK measuring wheel premounted; Standard reference device: DFS60B-S4PC10000, 1036721; Performance: Pulses per revolution: 7,500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL...