[siemens_summary]
[catalog_children]
[catalog_search_products]

Incremental encoders ⍾ Page 235

Product detailsAdd to RFQ
DFS60B-S4PC10000 - Sick
DFS60, Rotary. Electrical interface: 4.5 V ... 32 V, TTL/HTL programmable, Connector M12, 8-pin, radial.
Product detailsAdd to RFQ
DFS60B-S4EN00360 - Sick
Performance: Pulses per revolution: 360 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-S4EN08192 - Sick
Performance: Pulses per revolution: 8,192 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60B-S4EZ00S80 - Sick
Features: Special device: ✔; Specialty: Cable, 8-wire, with universal M12 8-pin male connectorTotal length including connector 130 mm. M12 connector must be protected by an additional strain relief; Standard reference device: DFS60B-S4EA00006, 1037261; Performance: Pulses per revolution: 6 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interfaces: Communication...
Product detailsAdd to RFQ
DFS60B-S4EM03000 - Sick
Performance: Pulses per revolution: 3,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-S4EN00800 - Sick
Performance: Pulses per revolution: 800 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-S4EM04096 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 5 m.
Product detailsAdd to RFQ
DFS60B-S4EM10000 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 5 m.
Product detailsAdd to RFQ
DFS60B-S4EM05000 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 5 m.
Product detailsAdd to RFQ
DFS60B-S4EM01000 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 5 m.
Product detailsAdd to RFQ
DFS60B-S4EM01200 - Sick
Performance: Pulses per revolution: 1,200 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-S4EM00720 - Sick
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 5 m.