[siemens_summary]
[catalog_children]
[catalog_search_products]

Incremental encoders ⍾ Page 325

Product detailsAdd to RFQ
DFS60B-BDEC02500 - Sick
Performance: Pulses per revolution: 2,500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-BDCL01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without load);...
Product detailsAdd to RFQ
DFS60B-BDEA00030 - Sick
Performance: Pulses per revolution: 30 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-BDEA10000 - Sick
Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-BDEA00S81 - Sick
Features: Special device: ✔; Specialty: Blind hollow shaft: different diameters realized by using colletsShaft fixation by compression of collet from the back side of the encoderIntegrated stator coupling; Standard reference device: DFS60B-BDEA01000, 1053126; Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication...
Product detailsAdd to RFQ
DFS60B-BDCC03600 - Sick
Performance: Pulses per revolution: 3,600 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60B-BDCC04096 - Sick
Performance: Pulses per revolution: 4,096 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without load);...
Product detailsAdd to RFQ
DFS60B-BDCK03600 - Sick
Performance: Pulses per revolution: 3,600 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60B-BDCM01000 - Sick
Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60B-BCPK10000 - Sick
DFS60, Rotary. Electrical interface: Cable, 8-pin, universal, 1.5 m, TTL/HTL programmable.
Product detailsAdd to RFQ
DFS60B-BDCA06000 - Sick
Performance: Pulses per revolution: 6,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60B-BDCA03600 - Sick
Performance: Pulses per revolution: 3,600 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...